771557
7
Zoom out
Zoom in
Previous page
1/12
Next page
5
Table 5-2 (10/12KW)
No. Fault or protection type Recovery mode Error code
1Communication fault between main control board and communication
terminals block Recoverable C0
2 IDU communication error Recoverable E2
3 T3 or T4 temperature sensor error Recoverable E4
4 Input voltage protection Recoverable E5
5 DC fan protection Recoverable E6
6 EEPROM error Unrecoverable E9
7 Wrong compressor parameters Unrecoverable E.9.
8 E6 fault occurs more than six times in an hour. Unrecoverable Eb
9 PFC fault Unrecoverable EF
10 Refrigerant radiator temperature sensor error Recoverable EH
11 Cooling ambient temperature lower than -5°C Recoverable EP
12 DC bus voltage protection Recoverable F1
13 Communication between the main control board and the inverter fails. Recoverable H0
14 M-Home mismatch(reserved) Recoverable HF
15 L (L0/L1) fault occurs three times in one hour. Unrecoverable H4
16 The fault is increased or reduced on the IDU. Recoverable H7
17 IPM protection Recoverable L0
18 DC bus low voltage protection Recoverable L1
19 DC bus high voltage protection Recoverable L2
20 MCE error Recoverable L4
21 Zero speed protection Recoverable L5
22 Compressor phase sequence error Recoverable L7
23 Protection for compressor speed change > 15Hz Recoverable L8
24 Protection for the di󰀨erence between the set speed and the running speed
of the compressor > 15Hz Recoverable L9
25 Radiator surface temperature protection Recoverable PL
26 System high pressure protection Recoverable P1
27 System low pressure protection Recoverable P2
28 Overcurrent protection Recoverable P3
29 Discharge temperature T5 protection Recoverable P4
30 Outdoor condenser temperature T3 protection Recoverable P5
31 Typhoon protection Recoverable P8
32 IDU evaporator temperature T2 protection Recoverable PE
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun Mini Amazon III - KMF at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun Mini Amazon III - KMF in the language / languages: English as an attachment in your email.

The manual is 1.07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun Mini Amazon III - KMF

Kaysun Mini Amazon III - KMF User Manual - German - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info