771438
23
Zoom out
Zoom in
Previous page
1/40
Next page
Indoor Unit
Installation
8. Remove the side board and the grille.
Screw nut
Washer
Hanging screw bolt
Overhang part
Shockproof cushion
NOTE: Conrm the minimum drain tilt is 1/100 or
more.
9. Mount the indoor unit onto the hanging
screw bolts with a block.
Position the indoor unit on a at level by using
a level to prevent leaks.
Ceiling Installation
20mm
D. Refrigerant pipe
connection
(D.gas side)
Drain point
Downward slope between(1-2)/100
E. Refrigerant pipe
connection
(E. Liquid side)
The conduit
installation plate
Cord conduit
Side board
The conduit
installation plate
screws
(not supply)
screws
(not supply)
The conduit
installation plate
Chassis
Hanging arm
Hanging
screw bolt
Wall-Mounted Installation
How to install the conduit installation plate
(if supplied)
1. Fix the sheath connector (not supply) on the
wire hole of the conduit installation plate.
2. Fix the the conduit installation plate on the
chassis of the unit.
How to install the conduit installation plate
(if supplied)
1. Fix the sheath connector (not supply) on the
wire hole of the conduit installation plate.
2. Fix the conduit installation plate on the electric
control box.
The electric control box
Page 23
23


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun KPC-105 DR13 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun KPC-105 DR13 in the language / languages: English as an attachment in your email.

The manual is 14.89 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun KPC-105 DR13

Kaysun KPC-105 DR13 User Manual - German - 40 pages

Kaysun KPC-105 DR13 User Manual - Dutch - 40 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info