Maintenance
Maintenance tips
- Be sure to clean the air filter every 2 weeks for opti-
mal perfomance.
- The water collection tray should be drained imme-
diately after P1 error occurs, and before storage to
prevent mold.
- In households with animals, you will have to periodi-
cally wipe down the grill to prevent blocked airflow fue
to animal hair.
Clean the Unit
Clean the unit using a damp, lint-free cloth and mild
detergent. Dry the unit with a dry, lint-free cloth.
Storafe the unit when not in use
- Drain the unit’s water collection tray according to the
instructions in the following section.
- Run the appliance on FAN mode for 12 hours in a
warm room to dry it and prevent mold.
- Turn off the appliance and unplug it.
- Clean the air filter according to the instructions in the
previous section. Reinstall the clean, dry filter before
storing.
- Remove the batteries from the remote control.
Be sure to store the unit in a cool, drak place. Exposu-
re to direct sunshine or extreme heat can shorten the
lifespan of the unit.
NOTE: The cabinet and front may be dusted with an
oil-free cloth or washed with a cloth dampened in a so-
lution of warm water and mildliquid dishwashing deter-
gent. Rinse thoroughly and wipe dry. Never use harsh
cleansers, wax or polish on the cabinet front. Be sure to
wring excess water from the cloth before wiping around
the controls. Excess water in or around the controls
may cause damage to the unit.
Faults Diagnosis
Please check the machine according to the following form before asking for maintenance:
Problem Possible Cause Troubleshooting
Unit does not turn on
when pressing ON/
OFF button
P1 Error Code
The Water Collection Tray is full. Turn off the unit,
drain the water from the Water Collection Tray and
restart the unit.
In COOL mode: room temperature is
lower than the set temperature
Reset the temperature.
Unit does not cool
well
The air filter is blocked with dust or
animal hair
Turn off the unit and clean the filter according to
instructions
Exhaust hose is not connected or is
blocked
Turn off the unit, disconnect the hose, check for bloc-
kage and reconnect the hose
The unit is low on refrigerant
Call a service technician to inspect the unit and top off
refrigerant
Temperature setting is too high Decrease the set temperature
The windows and doors in the room are
open
Make sure all windows and doors are closed
The room area is too large Double-check the cooling area
There are heat sources inside the room Remove the heat sources if possible
The unit is noisy and
vibrated too much
The ground is not level Place the unit on a flat, level surface
The air filter is blocked with dust or
animal hair
Turn off the unit and clean the filter according to
instructions
The unit makes a
gurgling sound
This sound is caused by the flow of
refrigerant inside the unit
This is normal
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun KP-35 CP10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun KP-35 CP10 in the language / languages: English as an attachment in your email.

The manual is 2,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun KP-35 CP10

Kaysun KP-35 CP10 User Manual - German - 20 pages

Kaysun KP-35 CP10 User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info