Special requirements for R32
The appliance shall be stored so as to prevent mechanical damage and in a well-ventilated room without
continuously operating ignition sources (example:open flames,an operating gas appliance) and have a room size
as specified below.
WARNING
Do NOT re-use joints which have been used already.
Joints made in installation among parts of refrigerant system shall be accessible for maintenance purposes.
NOTE
Make sure installation,servicing,maintenance and repair comply with instractions and with applicable legislation
(for example national gas regulation) and are executed only by authorised persons.
WARNING
Pipework should be protected from physical damage.
Installation of pipework should be kept to a minimum.
NOTE
If the total refrigerant charged in the system is ≤1.842 kg , there are no additional minimum floor area requiements.
If the total refrigerant charged in the system is 1.842 kg, you need to comply with additional minimum floor area
requirements as describrd in the following flow chart. The flow chart uses the following tables: “Table 1-Maximum
refrigerant charge allowed in a room: indoor unit” on page 5, “Table 2-Minimum floor area: indoor unit” on page 5 and “Table
3-Minimum venting opening area for natural ventilation: indoor unit” on page 5.
WARNING
Refrigerant leakage and open flame are not allowed.
Be aware that the R32 refrigerant does NOT contain an odour.
03
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun KHPI-BI-10VR2XL at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun KHPI-BI-10VR2XL in the language / languages: English as an attachment in your email.

The manual is 38.52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun KHPI-BI-10VR2XL

Kaysun KHPI-BI-10VR2XL User Manual - German - 44 pages

Kaysun KHPI-BI-10VR2XL User Manual - Dutch - 44 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info