771475
36
Zoom out
Zoom in
Previous page
1/48
Next page
34
Product fiche 1
Heat pump space heater
Outdoor
KEM-05 DVN1
KEM-07 DVN1
KEM-10 DVN
KEM-12 DVN
Indoor
-
-
-
-
Indoor unit sound power (*)
[dB(A)]
-
-
-
-
Outdoor unit sound power (*)
[dB(A)]
63.0
66.0
68.0
68.0
Space heating
Energy efficiency class 35°C (Low temp. app.)
-
A+
A+
A+
A+
Average climate (Design temperature = 10°C)
Space heating 35°C
Prated (declared heating capacity) @ 10°C
[kW]
6.2
8.0
11.0
12.3
Seasonal space heating efficiency (ηs)
[%]
139
135
131
135
Annual energy consumption ion
[kWh]
3,600
4,750
6,900
7,400
Warmer climate (Design temperature =2°C)
Space heating 35°C
Prated (declared heating capacity) @ 2°C
[kW]
5.1
6.8
9.0
9.3
Seasonal space heating efficiency (ηs)
[%]
169
165
161
164
Annual energy consumption
[kWh]
1,125
1,484
2,155
2,312
Ecodesign technical data
Product description
Air-to-water heat pump
Y/N
Yes
Yes
Yes
Yes
Water-to-water heat pump
Y/N
No
No
No
No
Brine-to-water heat pump
Y/N
No
No
No
No
Low-temperature heat pump
Y/N
Yes
Yes
Yes
Yes
Equipped with a supplementary heater
Y/N
Yes
Yes
Yes
Yes
Heat pump combination heater
Y/N
No
No
No
No
Air to water unit
Rated airflow (outdoor)
[m3/h]
3200
3750
4800
4800
Brine/water to water unit
Rated water/brine flow (outdoor H/E)
Other
Capacity control
-
Poff (Power consumption Off mode)
[kW]
0.011
0.011
0.018
0.018
Pto (Power consumption Thermostat off mode)
[kW]
0.005
0.005
0.023
0.023
Psb (Power consumption Standby mode)
[kW]
0.011
0.011
0.019
0.019
PCK (Power crankcase heater model)
[kW]
0.032
0.032
0.060
0.060
Qelec (Daily electricity consumption)
[kWh]
Qfuel (Daily fuel consumption)
[kWh]
Part load conditions space heating average climate
(A) condition (-7°C)
Pdh (declared heating capacity)
[kW]
5.51
5.70
10.20
10.50
COPd (declared COP)
-
2.50
2.30
2.30
2.25
Cdh(degradation coefficient)
-
0.90
0.90
0.90
0.90
(B) condition (2°C)
Pdh (declared heating capacity)
[kW]
3.59
4.40
6.10
3.80
COPd (declared COP)
-
3.88
3.48
3.20
3.35
Cdh(degradation coefficient)
-
0.90
0.90
0.90
0.90
(C) condition (7°C)
Pdh (declared heating capacity)
[kW]
2.20
2.90
3.80
4.40
COPd (declared COP)
-
4.56
5.60
4.75
5.00
Cdh(degradation coefficient)
-
0.90
0.90
0.90
0.90
(D) condition (12°C)
Pdh (declared heating capacity)
[kW]
1.06
1.29
2.10
2.10
COPd (declared COP)
-
4.15
4.30
4.70
5.15
Cdh(degradation coefficient)
-
0.90
0.90
0.90
0.90
(E) Tol (temperature operating limit)
Tol (temperature operating limit)
[°C]
-10.00
-10.00
-10.00
-10.00
Pdh (declared heating capacity)
[kW]
5.10
5.45
9.50
10.00
COPd (declared COP)
-
2.45
2.30
2.25
2.15
WTOL (Heating water Operation Limit)
[°C]
52.00
52.00
52.00
52.00
(F) Tbivalent temperature
Tblv
[°C]
-7.00
-4.00
-7.00
-6.00
Pdh (declared heating capacity)
[kW]
5.51
6.26
10.20
10.90
COPd (declared COP)
-
2.50
2.54
2.30
2.35
Capacity of the back-up heater integrated in the unit
Psup back-up heater (@Tdesignh: 10°C)
[kW]
3.00
3.00
4.50
4.50
Supplementary capacity at P_design
Psup (@Tdesignh: 10°C)
[kW]
1.10
2.55
1.50
2.30
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun KEM-14 DTN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun KEM-14 DTN in the language / languages: English as an attachment in your email.

The manual is 7.07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun KEM-14 DTN

Kaysun KEM-14 DTN User Manual - Dutch - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info