771471
30
Zoom out
Zoom in
Previous page
1/48
Next page
29
NO.
Icon
Description
20
Frequency unit icon
It will be constantly light when the control panel displays frequency of the compressor.
21
ON/OFF and OK button
1.Press ” to confirm the former operation when finishing the setting work.
2.Long press ” for 3S will recovers to factory default mode.
22
Mode choice function/Function choice/Back function button
1.Mode choice function. Choose operation mode.
2. Function choice. Long press it for 3s to enter function setting in the main interface.(Clock setting, Timing on and timing off
setting)
3. Back to the previous menu. Long press it for 3s to back to previous menu in the function setting interface. Top menu is the
main interface.
23
Up
1.(Value increase)
2.Forward to the previous interface.
24
Down
1.(Value decrease)
2.Backward to the next interface.
7.2.2 Control panel operation description
1. ON/OFF
The first time to powered on the unit,
Operation panel displays “OFF”. Long press for 3s,
to unlock “OFF” status and enter into standby status.
Power on: In the standby status, press ” to enter mode
choice function. Press “ ” circularly to choose one kind
of “power on” mode, the mode icon will flicker at the moment.
Press “ to confirm the power on mode. The unit will run
as the chosen mode when the mode icon will be constantly light.
Power off: Press ” in the main interface to enter mode
choice function and the icon which indicate the current mode will
flicker. Press circularly to choose power off mode,
” will flicker at this moment. Press ” button to
and go to the next step.
By this time, the last 2 digits of the nixie tube will flicker and
press ” or “ ” to adjust temperature and set the
temperature of the inlet water. Press ” to confirm and
move to the next step.
By this time, the first 2 digits of the nixie tube will flicker and
press or “ to adjust time of timing on. Press
to confirm and switch to minute setting automatically. The last 2
digits of the nixie tube will flicker and press or “ ” to
adjust minute setting of timing on.(minimal unit of minute
adjustment: 15 minutes) .
Press “ ” to confirm. The first group setting is finished and
” will be constantly light. When processing the second
timing setting, repeat the 1-2 operation above. When the nixie
confirm the power off mode. By this time,
light and the unit stops.
2. Mode choice and temperature settings
will be constantly tube displays “01” and flicker, press “ or ” to choose
the timing on group. When the nixie tube displays “ 02 ” which
means setting timing on function of the second group.
Refers the timing on setting operation of group 1 to set that of
group 2.
Press “ ” in the main interface to enter mode choice
function. The “Mode” icon will flicker. Click ” circularly to
choose a mode. The circulating order is “Cooling mode”→
“Heating mode”→“Water pump mode” →“Power off mode”
“Cooling mode”. The chosen mode will flicker.
Press “ ”or ”to increase/decrease the temperature in
the chosen mode.
Press “ ” to confirm power off mode and the set
temperature. Mode icon will be constantly light and the unit will
run as the chosen mode.
Press “ or in the main interface to increase/decrease
the temperature in the chosen mode.
3. Clock setting
Long press ” for 3s to enter function interface.
clock icon will flicker. Press ” to enter clock setting
function. “ ” icon will be constantly light and the first 2 digits
on nixie tube will flicker. Press or ” to set minute.
Press “ ” when finish setting and ” will be
extinguished.
4. Timing setting 1
Timing on setting
Long press ” for 3s to enter function interface.
clock icon will flicker. Press ” again to enter timing on
function. “ ” will flicker and press ” to enter timing
on setting.
At this moment, last 2 digits of the nixie tube display “01” which
means the first group setting begins. Press ” to the next
step.
By this time, mode icon will flicker and press ” to
choose timing on mode. Press ” to confirm your choice
30


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun KEM-07 DVN1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun KEM-07 DVN1 in the language / languages: English as an attachment in your email.

The manual is 7.07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun KEM-07 DVN1

Kaysun KEM-07 DVN1 User Manual - Dutch - 48 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info