Front cover installation
1) After adjusting the front cover and then buckle the front cover; avoid clamping the communication
switching wire during installation.
2) Correct install the back cover and firmly buckle the front cover and back cover, if not you maybe
make the front cover drop off.
Wired controller initial parameters setting:
1. Change the related functions of the controller through adjusting the initial parameters, details refer to
table 1
2. The wired controller initial parameter includes two codes "XY", the first code "X" means function
class, and the second code "Y" means the detailed configuration of this function.
3. Setting method:
1Simultaneously press "Mode" and "Fan" button of the wired controller for 5 seconds to enter the
parameter setting state;
2) The value of this first code "X" is "0"; press the temperature setting button UP and DOWN to adjust
the second code value;
3) After setting the second code value, press 26/OK button to switch the first code to the next value;
4) When the first code value is "6", press 26/OK button again to exit the parameters setting.
4. The parameters setting function only under the situation which needs to adjust the default functions'
setting states; otherwise there is no need to do the setting.
Tab le 1
First
code
Functions
Second code
0
1
2
3
4
0
Cool-only/ Cool-Heat
selection
Cool-Heat
(Default)
Cool-only
/
/
1
Indoor unit communication
address setting
Yes (Default)
None
/
/
/
2
Auto-restart
Yes (Default)
None
/
/
/
3
Air filter cleaning reminding
function
Cancel the
reminding
function
1250 hours
2500 hours
(Default)
5000
hours
10000
hours
5
Remote receiving function
Yes (Default)
None
/
/
/
6
Centigrade/
Fahrenheit display
Centigrade
Fahrenheit
/
/
/
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun KCT-02.1 SR at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun KCT-02.1 SR in the language / languages: English as an attachment in your email.

The manual is 0.88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun KCT-02.1 SR

Kaysun KCT-02.1 SR User Manual - Dutch - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info