771521
27
Zoom out
Zoom in
Previous page
1/80
Next page
23
9.3.1 Main control board of indoor unit
3029 32
25 26 27 28
31
7
1211
109
18
8
7
5
2322 24
1 2
13
346
2014 15 17 1916 21
6 8 9 10
5
4321
CN4
CN22
CN5
S3
DIS1
CN24
CN1
CN2
CN6
CN8
CN13
CN15
CN16
CN18
CN28
S2
CN42
CN21
S1
S4
CN11 CN7
CN17
CN19
CN30
CN35
CN14
CN31
CN36
145
2 3
22
CN25
6
CN29
CN40
CN41
910
11
12
13
14
15
17
18
19
7 8
16
20
21
23
24
25
26
27
28
29
30
31
CN32
32
SW9
Assembly unit Assembly unitOrder Order
1
2
3
4
5
8
10
16
17
19
20
21
22
23
24
Port for power supply
Digital display
Port for ground
Port for
variable speed
pump power input
Port for temperature sensors of refrigerant liquid
side temperature of indoor unit (heating mode)
Port for temperature sensors of refrigerant gas
side temperature of indoor unit (cooling mode)
Port for temperature board
Communicate port between indoor unit and
outdoor unit
Port for antifreeze E-heating tape(external)
Port for SV2(3-way valve)
Port for zone 2 pump
Port for outside circulation pump
Feedback port for external temperature
switch(shorted in default)
Feedback port for temperature switch
(shorted in default)
Reserved
Control port for tank booster heater
6
25
26
27
28
Port for temperature sensors of outlet water
temperature of plate heat exchanger
Port for temperature sensors of inlet water
temperature of plate heat exchanger
Port for temperature sensors of final outlet
water temperature of indoor unit
Dip switch
Port for USB programming
Port for flow switch
Port for IC programming
Rotary dip switch
9
11 Port for balanced water tank of up temp. sensor
12 Port for balanced water tank of dowm temp.
sensor
13 Port for domestic hot water tank temp. sensor
14 Port for outlet water for zone 2 temp. sensor
Port for solar panel temp. sensor
Port for
variable speed
pump communication
Control port for room thermostat (heating mode)
Power port for room thermostat
Control port for room thermostat (cooling mode)
18 Port for smart grid (photovoltaic signal)
Port for smart grid (grid signal)
Port for solar energy pump
Port for DHW pipe pump
Control port for tank booster heater
Control port for internal backup heater 1
Port for SV3(3-way valve)
Control port for internal backup heater 1
29
30
31
Port for anti-freeze electric heating tape(internal)
Port for anti-freeze electric heating tape(internal)
Port for anti-freeze electric heating tape(internal)
Port for anti-freeze electric heating tape(internal)
32
CN21 POWER
S3 /
DIS1
CN5 GND
CN28 PUMP
CN25 DEBUG
CN4 USB
FS
T2
T2B
TW_in
TW_out
T1
CN6
CN19
CN14
27 28
1 2
3 4 15
5 6 16
7 8 17
9 21
10 22
IBH1/2_FB
IBH1
IBH2
TBH
TBH_FB
25 29
CN7
CN11
CN2
CN1
CN22
Port Port
Code Code
Port for communication with the wired controller
Port for Internal machine Parallel
Compressor run/Defrost run
Port for additional heat source
Input port for solar energy
Port for room thermostat
Port for SV1(3-way valve)
/
7S1,S2,S4,SW9 /
CN8
CN24 Tbt1
CN16 Tbt2
CN13 T5
CN15 Tw2
15 CN18 Tsolar
CN17 PUMP_BP
CN31
HT
COM
CL
CN35
SG
EVU
CN36 M1 M2 Port for remote switch
T1 T2
P Q
A B X Y E
CN30
1 2 3 4 5 Port for communication with the wired controller
6 7 Communicate port between indoor unit and
outdoor unit
9 10
26 30/31 32
11 23
12 24
13 16
14 17
18 19 20
CN41
CN40
CN42
CN29
HEAT8
HEAT7
HEAT6
HEAT5
CN32 IBH0 Port for backup heater
27


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun Aquantia PRO Monobloc - KHP-MO at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun Aquantia PRO Monobloc - KHP-MO in the language / languages: English as an attachment in your email.

The manual is 27.62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun Aquantia PRO Monobloc - KHP-MO

Kaysun Aquantia PRO Monobloc - KHP-MO User Manual - German - 88 pages

Kaysun Aquantia PRO Monobloc - KHP-MO User Manual - Dutch - 88 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info