771523
43
Zoom out
Zoom in
Previous page
1/76
Next page
39
RT1
Kamerthermostaat type 2 (laagspanning):
3029 32
25 26 27 28
31
7
1211
109
18
8
7
5
2322 24
1 2
13
346
2014 15 17 1916 21
6 8 9 10
5
4321
CN4
CN22
CN5
S3
DIS1
CN24
CN1
CN2
CN6
CN8
CN13
CN15
CN16
CN18
CN28
S2
CN42
CN21
S1
S4
CN11 CN7
CN17
CN19
CN30
CN35
CN14
CN31
CN36
CN25
CN29
CN40
CN41
CL COM HT
EVU SG
CLHT COM
CL
COM
RT1 RT2
3029 32
25 26 27 28
31
7
1211
109
18
8
7
5
2322 24
1 2
13
346
2014 15 17 1916 21
6 8 9 10
5
4321
CN4
CN22
CN5
S3
DIS1
CN24
CN1
CN2
CN6
CN8
CN13
CN15
CN16
CN18
CN28
S2
CN42
CN21
S1
S4
CN11 CN7
CN17
CN19
CN30
CN35
CN14
CN31
CN36
CN25
CN29
CN40
CN41
CL COM HTEVU SG
Afhankelijk van de toepassing zijn er drie methoden om de
thermostaatkabel aan te sluiten (zoals beschreven in de
bovenstaande afbeelding).
Methode A
RT kan verwarming en koeling afzonderlijk regelen, zoals de
regelaar voor 4 leidingen FCU. Wanneer de binnenunit is
aangesloten met de externe temperatuurregelaar,
gebruikersscherm VOOR SERVICEMAN stel ROOM
THERMOSTAT in op MODE SET:
A.1. Wanneer de unit een spanning van 12VDC tussen CL en
COM detecteert werkt de unit in de koelmodus.
A.2. Wanneer een spanning van 12 VDC tussen HT en COM
wordt gemeten, werkt de unit in de verwarmingsmodus.
A.3. Wanneer een spanning van 0 VDC voor beide zijden (CL-
COM, HT-COM) wordt gemeten, werkt de unit niet meer in
koel- of verwarmingsmodus.
A.4. Wanneer de unit een spanning van 12 VDC detecteert
tussen beide zijden (CL-COM, HT-COM) werkt de unit in de
koelmodus.
Methode B
RT geeft het schakelsignaal aan de unit. Gebruikersscherm
VOOR SERVICEMAN stel de KAMERTHERMOSTAAT in
op ÉÉN ZONE:
B.1. Wanneer de unit een spanning van 12 VDC tussen HT
en COM meet, wordt de unit ingeschakeld.
B.2. Wanneer tussen HT en COM een spanning van 0 VDC
wordt gedetecteerd, wordt de unit uitgeschakeld.
RT1
3029 32
25 26 27 28
31
7
1211
109
18
8
7
5
2322 24
1 2
13
346
2014 15 17 1916 21
6 8 9 10
5
4321
CN4
CN22
CN5
S3
DIS1
CN24
CN1
CN2
CN6
CN8
CN13
CN15
CN16
CN18
CN28
S2
CN42
CN21
S1
S4
CN11 CN7
CN17
CN19
CN30
CN35
CN14
CN31
CN36
CN25
CN29
CN40
CN41
CL COM HTEVU SG
HT COM
De binnenunit is verbonden met twee kamerthermostaten,
terwijl het gebruikersscherm VOOR SERVICEMAN de
KAMERTHERMOSTAAT instelt op DUBBELE ZONE:
C.1. Wanneer de unit een spanning van 12 VDC tussen HT
en COM detecteert wordt zone 1 ingeschakeld. Wanneer een
spanning tussen HT en COM van 0 VDC is wordt
gedetecteerd, wordt zone1 uitgeschakeld.
(modusinstelling)
Zone 1 Zone 2
HT
Methode C
(dubbele zone besturing)
CN32
SW9
CN32
SW9
CN32
SW9
Methode A
(modusinstelling)
POWER IN POWER IN POWER IN
Methode B
(bediening voor één zone) POWER IN
(bediening voor één zone)
Methode C (dubbele zone besturing)
43


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun Aquantia Pro Bibloc Wall mounted Indoor KHPM-BI at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun Aquantia Pro Bibloc Wall mounted Indoor KHPM-BI in the language / languages: Dutch as an attachment in your email.

The manual is 29.9 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun Aquantia Pro Bibloc Wall mounted Indoor KHPM-BI

Kaysun Aquantia Pro Bibloc Wall mounted Indoor KHPM-BI User Manual - English - 76 pages

Kaysun Aquantia Pro Bibloc Wall mounted Indoor KHPM-BI User Manual - German - 76 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info