owner's manual
2
1.1
Electrical safety requirements
1.
Wiring job must be done by the certified electrician.
2.
Wiring work must comply to electrical safety specifications.
3.
Be sure the air conditioner is grounded well which means the
main power switch of air-conditioner grounded with reliable
grounded wire.
4.
Make sure the min. space between PTC electrical heating
elements and flammable surface is>12mm.
5.
Apply separate power which meet the rated parameters for the
air-conditioner
1.2 Electrical performance requirements
Table 1-1
After a long use, check the unit stand and fitting for
damage.
If damaged, the unit may fall and result in injury.
To avoid oxygen deficiency, ventilate the room sufficiently
if equipment with burner is used together with the air
conditioner.
Arrange the drain hose to ensure smooth drainage.
Incomplete drainage may cause wetting of the building,
furniture etc.
Never touch the internal parts of the controller.
Do not remove the front panel. Some parts inside are
dangerous to touch, and a machine trouble may happen.
Never expose little children, plants or animals directly to
the air flow.
Adverse influence to little children, animals and plants may
result.
Do not allow a child to mount on the outdoor unit or
avoid placing any object on it.
Falling or tumbling may result in injury.
Do not operate the air conditioner when using a room
fumigation - type insecticide.
Failure to observe could cause the chemicals to become
deposited in the unit, which could endanger the health of those
who are hypersensitive to chemicals.
Do not place appliances which produce open fire in
places exposed to the air flow from the unit or under the
indoor unit.
It may cause incomplete combuston or deformation of the unit
due to the heat.
Do not install the air conditioner at any place where
flammable gas may leak out.
If the gas leaks out and stays around the air conditioner, a fire
may break out.
This appliance can be used by children age from 8 years
and above and persons with reduced physical,sensory or
mental capabilities or lack of experience and knowledge if
they have been given supervision or instruction
concerning use of the appliance in a safe way and
understand the hazards involved,children should not play
with This appliance.Cleaning and user maintenance
should not be made by children without supervision.
When capacity of indoor unit greater than the sum of
100%, capacity of indoor unit will be attenuated.
When capacity of indoor unit greater than or equal to the
sum of 120%, in order to ensure the effectiveness of
machine, and then try to open the indoor units at different
time.
The outdoor unit window-shades should be periodic
cleaning in case of being jammed.
This window-shapes is heat dissipation outlet of components, if being
jammed will cause the components shorten their service life spans because
of overheated for a long time.
The temperature of refrigerant circuit will be high, please
keep the interconnection cable away from the copper
tube.
Poor environmental conditions, the appliance should be
maintained a month and a half or so; If the environment
con- dition is good, may be extended appropriately
maintenance cycle.
The A-weighted sound pressure level is below 70dB.
CAUTION
Under any situations, it can not break off the ground wire of
the main power switch.
Can not use broken power wire, if there is any broken wire
then change it immediately.
First use the unit or the unit under the power off state for a
long time, power on and pre-heat the unit at least 12 hours
before using.
2. OPERATION METHOD
2.1 Operation conditions under each mode
Use the unit in the following temperature for safe and effective
operation.
Table 2-1
Cooling
operation
Indoor temp. 21to 32
Outdoor temp.-5to 48
Heating
operation
Indoor temp. under 28, above 0
Outdoor temp.-15to 24
CAUTION
Protection device may start if running the unit outside the
above condition, which will prevent the unit from operation.
Under “Cool” operation, room relative humidity should be
less than 80%. If higher than 80%,the surface of indoor unit
may be condensed or the condensate will be blown from air
outlet.
If less than 80%, please move the air leading bar to the
largest air oultet position (which is vertical direction), and set
the fan speed to be “High”.
For the start-up of the outdoor unit as a minimum the
installation must have a demand of 20% of the capacity of
the outdoor unit in the models less than 40kW or a demand
of 10% of the capacity in the models of a capacity greater
than or equal to 40kW
Model Fuse(A) Power supply specification
33.5kW/40kW 40A
380-415V 3N~ 50Hz
45kW 50A
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun Amazon Unitario KMF-400 DN3 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun Amazon Unitario KMF-400 DN3 in the language / languages: English as an attachment in your email.

The manual is 2.13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun Amazon Unitario KMF-400 DN3

Kaysun Amazon Unitario KMF-400 DN3 User Manual - German - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info