771551
11
Zoom out
Zoom in
Previous page
1/12
Next page
For example, in early summer or winter.
Check and remove all objects that may clog the air inlets and outlets
of the indoor and outdoor units.
Clean the air filter and external shell of the unit. Please contact the
installation or maintenance personnel. The installation/operation
manual of the indoor unit includes maintenance tips and cleaning
procedures. Make sure that the clean air filter is installed in its
original position.
Turn on the main power supply 12 hours before this unit is operated
in order to ensure that the unit runs smoothly. The user interface is
displayed once the power is turned on.
For example, at the end of winter and summer.
Run the indoor unit in the fan mode for about half a day to dry the
internal parts of the unit.
Turn off the power supply.
Clean the air filter and external shell of the unit. Please contact the
installation or maintenance personnel to clean the air filter and
external shell of the indoor unit. The installation/operation manual of
the specialized indoor unit includes maintenance tips and cleaning
procedures. Make sure that the clean air filter is installed in its
original position.
This product contains fluorinated greenhouse gases as stipulated in
the Kyoto Protocol. Do not discharge the gas into the atmosphere.
Based on the applicable law, the refrigerant must be checked regularly
for leakages. Please contact the installation personnel for more
information.
The refrigerant in the air conditioner is relatively safer, and usually
does not leak. If the refrigerant leaks, and comes in contact with
burning objects in the room, it will produce harmful gases.
Shut down any flammable heating device, ventilate the room and
contact the agent of the unit immediately.
Do not use the air conditioner again until the maintenance
personnel has confirmed that the refrigerant leakage has been
sufficiently resolved.
This product contains the warranty card that was completed by the
agent during installation. The customer must check the completed
warranty card and keep it properly.
If you need to repair the air conditioner during the warranty period,
please contact the agent and provide the warranty card.
Warning
7.1 Maintenance after Unit has been Shut Down
for a Long Period
7.2 Maintenance Before Unit is Shut Down for
a Long Period
7.3 About the Refrigerant
7.4 After-sales Service and Warranty
7.4.1 Warranty period
In the following situations, the "maintenance cycle" and "replacement
cycle" may be shortened.
The unit is used in the following situations:
Temperature and humidity fluctuations are outside the normal
ranges.
Large power fluctuations (voltage, frequency, waveform distortion
etc.) (must not use the unit if the power fluctuations exceed the
allowed range).
Frequent collisions and vibrations.
The air may contain dust, salt, harmful gas or oil such as sulphite
and hydrogen sulphide.
Frequent on and off of unit or operating time is too long (in places
where the air conditioning is on for 24 hours a day).
As the use of the unit for many years will eventually lead to a dust
layer, the performance of the unit will degenerate to a certain extent.
As professional skills are needed to dismantle and clean the unit, and
for the optimal maintenance effects of this unit, please contact your
agent for more details.
When you request the agent for assistance, please remember to state:
Complete model name of the air conditioner.
Date of installation.
Details on the fault symptoms or errors, and any defects.
Do not attempt to modify, dismantle, remove, reinstall or repair
this unit, as the improper dismantling or installation may result
in electric shock or fire. Please contact the agent.
If the refrigerant accidentally leaks, make sure that there is no
fire around the unit. The refrigerant itself is completely safe,
non-toxic and non-flammable, but it will produce toxic gases
when it accidentally leaks and comes in contact with flammable
substances generated by existing heaters, and burning devices
in the room. You must get a qualified maintenance personnel to
verify that the point of leakage has been repaired or rectified
before you restore the operations of the unit.
Warning
7.4.2 Recommended maintenance and inspection
7.4.3 Shorter maintenance and replacement cycle
8
The partial units shall only be connected to an appliance suitable
for the same refrigerant.
This unit is a partial unit air conditioner, complying with partial unit
requirements of this International Standard, and must only be
connected to other units that have been confirmed as complying
to corresponding partial unit requirements of this International
Standard.
Warning
For equipment that contains fluorinated greenhouse gases in
quantities of 5 tonnes of CO2 equivalent or more,but of less than 50
tonnes of CO2 equipment,at least every 12 months, or where a
leakage detection system is installed, at least every 24 months.
For equipment that contains fluorinated greenhouse gases in
quantities of 50 tonnes of CO2 equivalent or more,but of less than
500 tonnes of CO2 equipment,at least every six months, or where
a leakage detection system is installed, at least every 12 months.
For equipment that contains fluorinated greenhouse gases in
quantities of 500 tonnes of CO2 equivalent or more,at least every
three months ,or where a leakage detection system is installed,
at least every six months.
Non-hermetically sealed equipment charged with fluorinated
greenhouse gases shall only be sold to the end user where evidence
is provide that the installation is to be carried out by an undertaking
certified person.
Only certificated person is allowed to do installation, operation and
maintenance.
This product has the fluorinated gas, it is forbidden to release to air.
Refrigerant type: R410A/8Kg
Volume of GWP: 2088; tonnes CO2 equivalent
GWP=Global Warming Potential
Attention:
Frequency of Refrigerant Leak Checks
7.3.1 Important information for the refrigerant
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun Amazon Unitario III at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun Amazon Unitario III in the language / languages: English as an attachment in your email.

The manual is 1.85 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun Amazon Unitario III

Kaysun Amazon Unitario III User Manual - German - 12 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info