771407
21
Zoom out
Zoom in
Previous page
1/36
Next page
CORRECT
Make sure there are no kinks
or dent in drain hose to ensure
proper drainage.
INCORRECT
Kinks in the drain hose
will create water traps.
INCORRECT
Kinks in the drain hose
will create water traps.
INCORRECT
Do not place the end of the
drain hose in water or in
containers that collect water.
This will prevent proper
drainage.
Page 21
Step 5: Connect drain hose
By default, the drain hose is attached to the left-hand side
of unit (when you're facing the back of the unit). However,
it can also be attached to the right-hand side. To ensure
proper drainage, attach the drain hose on the same side
that your refrigerant piping exits the unit. Attach drain
hose extension (purchased separately) to the end of drain
hose.
Wrap the connection point rmly with Teon tape to
ensure a good seal and to prevent leaks.
For the portion of the drain hose that will remain
indoors, wrap it with foam pipe insulation to prevent
condensation.
Remove the air lter and pour a small amount of
water into the drain pan to make sure that water ows
the unit smoothly.
NOTE ON DRAIN HOSE PLACEMENT
Make sure to arrange the drain hose according to the
following gures.
PLUG THE UNUSED DRAIN HOLE
To prevent unwanted leaks you mst
plug the unused drain hole with the
rubber plug provided.
BEFORE PERFORMING ANY
ELECTRICAL WORK, READ THESE
REGULATIONS
1. All wiring must comply with local and national
electrical codes, regulations and must be installed by
a licensed electrician.
2. All electrical connections must be made according
to the Electrical Connection Diagram located on the
panels of the indoor and outdoor units.
3. If there is a serious safety issue with the power supply,
stop work immediately. Explain your reasoning to the
client, and refuse to install the unit until the safety
issue is properly resolved.
4. Power voltage should be within 90-110% of rated
voltage. Insufcient power supply can cause
malfunction, electrical shock, or re.
5. If connecting power to xed wiring, install a surge
protector and main power switch with a capacity of
1.5 times the maximum current of the unit.
6. If connecting power to xed wiring, a switch or
circuit breaker that disconnects all poles and has
a contact separation of at leasr 1/8in (3mm) must
be incorporateed in the xed wiring. The qualied
technician must use an approved circuit breaker or
switch.
7. Only connect the unit to an individual branch circuit
outlet. Do not connect another appliaance to that
outlet.
8. Make sure to properly ground the air conditioner.
9. Every wire must be rmly connected. Loose wiring
can cause the terminal to overheat, resulting in
product malfunction and possible re.
10. Do not let wires touch or rest against refrigerant
tubing, the compressor, or any moving parts within
the unit.
11. If the unit has an auxiliary electrich heater, it must
be installed at least 1 meter (40in) away from any
combustible materials.
12. To avoid getting an electric shock, never touch the
electrical components soon after the power supply
has been turned off. After turning off the power,
always wait 10 minutes or more before you touch the
electrical components.
WARNING
BEFORE PERFORMING ANY ELECTRICAL OR
WIRING WORK, TURN OFF THE MAIN POWER TO
THE SYSTEM.
Step 6: Connect signal cable
The signal cable enables communication between the
indoor and outdoor units. You must rst choose the right
cable size before preparing it for connection
Cable Types
Indoor Power Cable (if applicable): H05VVF- or
H05V2V2-F.
Outdoor Power Cable: H07RN-F
Signal Cable: H07RH-F
21


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun AKAY-CF 35 DR10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun AKAY-CF 35 DR10 in the language / languages: English as an attachment in your email.

The manual is 3.88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun AKAY-CF 35 DR10

Kaysun AKAY-CF 35 DR10 User Manual - German - 36 pages

Kaysun AKAY-CF 35 DR10 User Manual - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info