771406
24
Zoom out
Zoom in
Previous page
1/36
Next page
60 cm (24 in) por
above
30 cm (12 in)
from back wail
30 cm (12 in)
on left
60 cm (24 in)
on right
200 cm (79 in)
in front
Wind
Bafe
Strong wind
Strong wind
Strong
wind
Page 24
8. Outdoor Unit Installation
Install the unit by following local codes and regulations,
there may be differ slightly between different regions:
Installation Instructions - Outdoor Unit
Step 1: Select installation location
Before installing the outdoor unit, you must choose an
appropriate location. The following are standards that will
help you choose an appropriate location for the unit..
Proper installation locations meet the following
standards:
5Meets all spatial requirements shown in Installation
Space Requirements above
5Good air circulation and ventilation
5Firm and solid - the location can support the unit
and will not vibrate
5Noise from the unit will not disturb others
5Protected from prolonged periods of direct sunlight
or rain
55 Where snowfall is anticipated, raise the unit
above the base pad to prevent ice buildup and
coil damage. Mount the unit high enough to be
above the average accumulated area snowfall. The
minimum height must be 18 inches.
DO NOT install unit in the following locations:
[Near an obstacle that will block air inlets and outlets
[Near a public street, crowded areas, or where noise
from the unit will disturb others
[Near animals or plants that will be harmed by hot
air discharge
[Near any source of combustible gas
[In a location that is exposed to large amounts of
dust [ In a location exposed to a excessive amounts
of salty
SPECIAL CONSIDERATIONS FOR
EXTREME WEATHER
If the unit is exposed to heavy wind:
Install unit so that air outlet fan is at a 90º angle to the
direction of the wind. If needed, build a barrier in front of
the unit to protect it from extremely heavy winds.
See Figures below.
If the unit is frequently exposed to heavy rain or snow:
Build a shelter above the unit to protect it from the rain or
snow. Be careful not to obstruct air ow around the unit.
If the unit is frequently exposed to salty air (seaside):
Use outdoor unit that is specially designed to resist
corrosion.
Step 2: Install drain join (Heat pump unit only)
Before bolting the outdoor unit in place, you must install
the drain joint at the bottom of the unit. Note that there are
two different types of drain joints depending on the type
of outdoor unit.
If the drain joint comes with a rubber seal (see Fig. A),
do the following:
1. Fit the rubber seal on the end of the drain joint that will
connect to the outdoor unit.
2. Insert the drain joint into the hole in the base pan of
the unit.
3. Rotate the drain joint 90º until it clicks in place facing
the front of the unit.
4. Connect a drain hose extension (not included) to
the drain joint to redirect water from the unit during
heating mode.
If the drain joint doesn't come with a rubber seal (see
Fig. B), do the following:
5. Insert the drain joint into the hole in the base pan of
the unit. The drain joint will click in place.
6. Connect a drain hose extension (not included) to
the drain joint to redirect water from the unit during
heating mode.
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun AKAY-CF 26 DR10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun AKAY-CF 26 DR10 in the language / languages: English as an attachment in your email.

The manual is 3.88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun AKAY-CF 26 DR10

Kaysun AKAY-CF 26 DR10 User Manual - German - 36 pages

Kaysun AKAY-CF 26 DR10 User Manual - Dutch - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info