771406
9
Zoom out
Zoom in
Previous page
1/36
Next page
SLEEP Operation
Cool mode (+1ºC/2ºF) per hour for the
rst two hours
Heat mode (-1ºC/2ºF) per hour for the
rst two hours
Set
temperatura Keep running
Saving energy during sleep
Range
Fig. A
Fig. B
Deector rod
Page 9
Other Features
Auto-Restart (some units)
If the unit loses power, it will automatically restart with the
prior settings once power has been restored.
Anti-mildew (some units)
When turning off the unit from COOL, AUTO (COOL), or
DRY modes, the air conditioner will continue operate at
very low power to dry up condensed water and prevent
mildew growth.
Wireless Control (some units)
Wireless control allows you to control your air conditioner
using your mobile phone and a wireless connection.
For the USB device access, replacement, maintenance
operations must be carried out by professional staff.
Louver Angle Memory (some units)
When turning on your unit, the louver will automatically
resume its former angle.
Refrigerant Leakage Detection (some units)
The indoor unit will automatically display "EC" or "EL0C" or
ash LEDS (model dependent) when it detects refrigerant
leakage.
Sleep Operation
The SLEEP function is used to decrease energy use while
you sleep (and don't need the same temperature setting
to stay comfortable). This function can only be activated
via remote control. And the Sleep function is not available
in FAN or DRY mode.
Press the SLEEP button when you are ready to go to
sleep. When in COOL mode, the unit will increase the
temperature by 1ºC (2ºF) after 1 hour, and will increase
an additional 1ºC (2ºF) after another hour. When in HEAT
mode, the unit will decrease the temperature by 1ºC (2ºF)
after 1 hour, and will decrease an additional 1ºC (2ºF)
after another hour.
The sleep feature will stop after 8 hours and the system
will keep running with nal situation.
Setting Angle of Air Flow
Setting vertical angle of air ow
While the unit is on, use the SWING/DIRECT button
on remote control to set the direction (vertical angle) of
airow. Please refer to the Remote Control Manual for
details.
NOTE ON LOUVER ANGLES
When using COOL or DRY mode, do not set louver at
too vertical an angle for long periods of time. This can
cause water to condense on the louver blade, which
will drop on your oor or furnishings.
When using COOL or HEAT mode, setting the louver
at too vertical an angle can reduce the performance
of the unit due to restricted air ow.
(The vertical louver auto swing is an optional function)
Setting horizontal angle of air ow
The horizontal angle of the airow must be set
manually. Grip the deector rod (See Fig. B) and
manually adjust it to your preferred direction.
For some units, the horizontal angle of the airow can
be set by remote control. Pleade refer to the Remote
Control Manual.
NOTE: Do not move louver by hand. This will cause the
louver to become out of sync. If this occurs, turn off the
unit and unplug it for a few seconds, then restart the unit.
This reset the louver.
CAUTION
Do not put your ngers in or near the blower and suction
side of the unit. The high-speed fan inside the unit may
cause injury.
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun AKAY-CF 26 DR10 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun AKAY-CF 26 DR10 in the language / languages: English as an attachment in your email.

The manual is 3.88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun AKAY-CF 26 DR10

Kaysun AKAY-CF 26 DR10 User Manual - German - 36 pages

Kaysun AKAY-CF 26 DR10 User Manual - Dutch - 36 pages


The manual is sent by email. Check your email