Technical Data
9
Technical Data
Power supply
Mains operation 230 VAC, 50/60 Hz
Battery operation Lead Battery 12 V/3.4 Ah
Dimensions Width 260 mm, Height 90 (120) mm, Depth 165 mm
incl. accessories (plus case)
Weight ca. 4.5 kg (incl. case)
Safety standards CE mark
Protection class II
VDE EN 61010
Display TFT screen, LCD alpha numeric, 2x16 characters, Bargraph
display, backlit
Temperature range +5 C to +45 C
Frequency range SAT 920 MHz...2150 MHz
TV 48 MHz...858 MHz
FM 88 MHz...108 MHz (48 MHz...858 MHz)
Channel configuration TV B standard 7 MHz
D/G/I/K standard 8 MHz
M/N/M1 standard 6 MHz
Frequency tuning SAT 0.125 MHz graduations
TV 50 kHz graduations
FM 50 kHz graduations
Measurement error SAT Max. ±2 dB
TV/FM Max. ±2 dB
RF input BNC 75 coaxial socket
RF input reducer 0 – 60 dB in 4 dB graduations
Level measurement range 30–120 dBµV
Measurement bandwidth SAT 6 MHz
SAT DVB 6 MHz
TV 250 kHz TV/DVB 6 MHz
FM 250 kHz
Measuring detector SAT Average value display
TV Maximum value display
FM Average value display
Voltage standing wave ratio > 6 dB
FM threshold SAT < 9 dB
Audio-IF bandwidth SAT 230 kHz/150 kHz
TV 230 kHz
FM 230 kHz
Audio Deemphasis SAT 50 µs
TV/FM 50 µs
Audio processing SAT FM audio processing 5.0 MHz…8.99 MHz in 10-kHz graduations
TV FM and Nicam in quasi-parallel audio mode
AM in parallel audio mode (L standard only)
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kathrein MSK 25 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kathrein MSK 25 in the language / languages: English as an attachment in your email.

The manual is 1,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kathrein MSK 25

Kathrein MSK 25 User Manual - German - 56 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info