MEASURING FUNCTION: SPECTRUM ANALYSIS
The softkey buttons “FULL”, “MEDIUM” and “SMALL” allow a display of three different ranges of
bandwidths (FULL=900-2,200 MHz, MEDIUM=centre ± 260 MHz, SMALL= ± 65 MHz).
The spectrum analyser takes the measuring frequency from the pre-set transponder.
SELECTION OF THE BANDWIDTH RANGE DISPLAY
Press the button to call up spectrum analyser mode.
LEVEL MEASUREMENT
The cursor buttons ▲▼ allow the reference level to
be changed within the range 60 dBμV to 120 dBμV,
in 10 dB steps.
MEDIUM SPAN frequency range: Centre ± 260 MHz
Setting the reference level
FULL SPAN frequency range: 900-2,200 MHz
The cursor buttons ◄► allow the marker in the
frequency to be changed. As soon as the demodulator
“Locked”, the marker bandwidth is set automatically
(here indicated graphically by a red triangle in the
background).
The IF to be measured can also be input directly using
the numeric keypad.
All measurement results of the newly set transponder
will be measured and displayed after the demodulator
has been “locked”.
40


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kathrein MSK 120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kathrein MSK 120 in the language / languages: English as an attachment in your email.

The manual is 1,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kathrein MSK 120

Kathrein MSK 120 User Manual - German - 64 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info