11
Scan
Span
Variabel: 10, 30, 100, 300 MHz
und full band (von 5…862 MHz)
Referenzpegel
Variabel von 60 bis 10 dBµV in 10
dB-Schritten
Tilt
Anzeige Numerisch und Pegelbalken
Analysierte Bänder
Vorwärtsband (45 bis 862 MHz) oder
Rückkanalband (5 bis 100 MHz)
Anzahl der Pilotkanäle 4 pro Band
Pilotfrequenz von 5 bis 862 MHz
Pilotauflösung 10 kHz
Spektrumanalysator
Span von 1 bis 00 MHz (1, 5, 15, 30, 50,
100 MHz)
Referenzpegel Variabel von 60 bis 120 dBµV in
10 dB Schritten
Analysierte Bänder
Vorwärtsband (45 bis 862 MHz) oder
Rückkanalband (5 bis 100 MHz)
Detektor Spitze oder Mittelwert
Bandbreite 230 kHz
Auflösung
Spitzenwertdetektor
Span 100 MHz 900 kHz
Span 50 MHz 450 kHz
Span 30 MHz 275 kHz
Span 15 MHz 135 kHz
Span 5 MHz 45 kHz
Span 1 MHz 10 kHz
Mittelwertdetektor
Span 30 MHz 280 kHz
Span 15 MHz 140 kHz
Span 5 MHz 50 kHz
Span 1 MHz 10 kHz
Transientenmessung
Ansprechschwelle von 20 bis 60 dBµV in 1 dB
Schritten
Messbereich von 5 bis max. 100 MHz
Anzeige
Anzahl der gemessenen Transi-
enten während der Messzeit, aktu-
eller und max. gemessener Pegel
während der Messzeit
Audio
Demodulation
AM / FM / LEVEL (variabler Ton
entsprechend dem Signalpegel)*
Ausgang
Interne Lautsprecher / externe
Kopfhörer
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kathrein MFK 11 - CATV-Analyzer at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kathrein MFK 11 - CATV-Analyzer in the language / languages: German as an attachment in your email.

The manual is 0,28 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info