936.2066/D/0805/7.20d.e.f.esp.
General
Only the power unit NCF 18 may be used in order to comply with the EMC requirements
Unoccupied subscriber outputs must be terminated with 75 Ω termination resistors EMK 03
Max. ambient temperature: -20 to +55 °C
RF and DC connections: F-connectors
Accessories (in the scope of delivery):
EXR 504: Power unit NCF 18
Application examples
Settings of the satelitte receiver
For optimal control of the series 500 switching matrices 500 series, you can effect the following
settings in the menu setting of your satellite receiver*):
Setting Effect
DiSEqC off Switch-over time of the receiver is reduced
22 kHz ––> High/Low For analogue and digital selection of a satellite
22 kHz ––> Pos A/B For selection of 2 satellites (Multifeed)
LNB voltage supply in stand-by mode set to off Power saving
*) Terms from the setting menu of other manufacturer’s satellite receivers can deviate from above terms
Minimal level at input of
EXR 504:
Sat 75 dBµV
VHF 80 dBµV
UHF 90 dBµV
Maximal cable length 75 m
Attention
Terrestrial
antenna
Sat IF 950-1950 MHz anlogue
Sat IF 1100-2150 MHz digital
Electronic equipment is not household waste – in accordance with directive 2002/96/EC OF THE EUROPEAN PARLIAMENT AND
THE COUNCIL of 27th January 2003 on used electrical and electronic equipment, it must be disposed of properly.
At the end of its service life, take this unit for disposal at a relevant official collection point.