5. Install Reject Brine Plumbing: The reject brine water can be teed into an existing
scupper or sink drain hose for draining overboard. Use the 3/8" reinforced hose and supplied
hose clamps. A tee of the correct size will have to be supplied. Alternatively, a dedicated thru-
hull may be installed at a convenient location. In this case, we recommend that a seacock be
installed at the thru-hull.
6. Install Product Freshwater Plumbing: Your product freshwater plumbing design
should allow for both saving and discarding of product freshwater. This normally requires (1) a
drain location and (2) a container for collecting good product freshwater.
In no case should the product freshwater hose be permanently plumbed into the ship’s potable
water storage tank(s), without providing a way to reject the product freshwater when necessary.
Note that product freshwater should always be rejected during the first few minutes after
startup, and especially after treating with membrane preservative or chemical cleaners. For that
reason alone, a means must be provided for disposing of unwanted product freshwater.
In general, we do not recommend that the output of product freshwater be routed directly into a
vessel’s freshwater storage tank(s). If for any reason the watermaker should fail during
operation, there is a good chance that the entire supply of freshwater in the storage tank could
become contaminated by unpurified seawater. This is especially important if:
you have only a single tank for storing potable water.
you will be making extended offshore passages and depending on your
watermaker for your potable water supply.
The preferred method for collecting product freshwater is to use portable 5- or 6-gallon jerry
jugs or a separate “day tank,” which is isolated from the main storage tank. Some method
should be devised for testing the product freshwater quality at the beginning and at the end of
each operation. When you are certain that the quality of the collected product freshwater is
acceptable, it can be transferred to the main storage tank.
Note: The important concept is to always have a minimum quantity of known-good potable
water available at all times, either in your main storage tank or in the collection container(s).
The length of your expected voyage and maximum distance from a source of potable water
will determine the size of the adequate minimum amount. Arrange your water making
schedule to assure that you always have the minimum of known-good potable water on
board in one or both of your containers.
To route the product freshwater output of their watermakers, many users simply run a single
3/16" I.D. hose directly from the output hose barb on the membrane housing to a single location,
where the water is tested and either discarded or run into a collection container.
Should you prefer to have your product freshwater output routed to two separate locations for
testing/discarding and collection, the watermaker system includes a product 3-way valve for use
in your output plumbing. Refer to Figure A-1 for a routing diagram.
8
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Katadyn PowerSurvivor 40E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Katadyn PowerSurvivor 40E in the language / languages: English as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Katadyn PowerSurvivor 40E

Katadyn PowerSurvivor 40E User Manual - German - 36 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info