522391
17
Zoom out
Zoom in
Previous page
1/36
Next page
1. Unscrew the prefilter housing, remove the dirty
prefilter element, and discard the water in the
bowl. Do not lose the large o-ring at the top of
the bowl.
Warning: If you purchase after-
market filter elements, be certain
they are made from polyester fibers.
In particular, be wary of elements
made of paper materials. They look
very similar, but are designed for
use with other types of water
purification systems and are harmful
to the membranes and high
pressure pumps used in reverse
osmosis watermakers. Be certain
you purchase only polyester filter
elements of 30-micron (or finer) size.
2. Clean the inside surface of the prefilter bowl.
Inspect and clean the o-ring at the top of the
bowl. Lubricate the o-ring and the threads of the
prefilter housing with a light coat of silicon
grease.
3. Install a clean filter element and screw the
prefilter bowl back on securely.
4. If the watermaker will not be used within the
next three days, treat it with membrane
preservative (see Membrane Storage below).
5. Tie a line through the center of the dirty filter
element and, if underway, tow it behind the vessel for a few minutes. If the vessel is
anchored, hang the dirty filter over the side of the boat so that it is underwater, and
jerk/shake it up and down a few times to dislodge the contaminants.
6. Dry the filter element thoroughly, preferably in the sun. Then store it for use as a clean
filter the next time the prefilter assembly is serviced.
We do not recommend scrubbing filter elements with brushes or other abrasive tools or
materials, as such treatment is unnecessary and greatly shortens the life of the filter element. If
filter elements are cleaned regularly as directed, and not allowed to become extremely dirty,
they can be expected to last for many months of service with nothing more than the gentle
cleaning described above. Clean filter elements also help assure unrestricted flow of intake
seawater to the pump.
Membrane Storage, Preserving & Cleaning
The reverse osmosis membrane element inside the membrane housing is an expensive and
delicate component of your system. When properly cared for, it can be expected to last for
several thousand hours of use. However, improper use, maintenance or handling can damage
or destroy it very quickly.
Membrane Preservative Treatment: The primary purpose
of a membrane preservative treatment is to keep
membrane moist and reduce biological growth on the
membrane surface. Over time, biological matter can
adhere to the membrane surface, thus gradually
decreasing its effectiveness. When the watermaker is not
to be used for an extended period of time, you should
preserve the membrane. A membrane preservative
treatment is effective for approximately one year (storage
temperature <25°C/77°F). If longer storage is required, the
membrane preservative treatment should be repeated
every year.
Warning: Be sure to follow the flushing procedures described below to ensure that the
membrane preservative solution does not get into the freshwater supply.
In temperate climates, the maximum period of time the watermaker should be stored without
preserving the membrane is approximately one week. In hot or tropical climates, the
watermaker membrane should be preserved if it will not be used within the next three days.
Follow these directions to preserve the membrane of your watermaker:
13
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Katadyn PowerSurvivor 160E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Katadyn PowerSurvivor 160E in the language / languages: English as an attachment in your email.

The manual is 0,88 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Katadyn PowerSurvivor 160E

Katadyn PowerSurvivor 160E User Manual - German - 34 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info