Field Performance Tips
The Katadyn Combi is designed to remove bacteria and protozoan cysts such
as Legionella, Giardia and Cryptosporidium. To extend ceramic life, always use the best
water source available. Keep the input prefilter clean and off the bottom. In heavy sediment con
ditions, wrap a coffee filter or bandanna around the input prefilter. Where possible, place untreat
ed water in container and wait for sediment to settle out until water appears clear  then filter from
water above the sediment.
Maintain your Katadyn water system to keep it operating smoothly.
1) If handle is hard to push
Clogged filter pores. If the filter pores of the ceramic are clogged, the ceramic needs to
be cleaned. Never use force when pumping. Remove ceramic element by turning the
filter base at lower end of housing counter clockwise one quarter turn (the bottom end of the
bottle adaptor may be used to aid turning). Clean the ceramic element by brushing it with
the supplied cleaning pad until the light, originally colour appears again. Insert the ceram
ic element into the housing. Push and turn the filter base clockwise one quarter turn.
Attention:
The filter housing can be under pressure  unfiltered water can splash out while
taking out the ceramic element.
2) Lubricate pump handle oring. Silicone lubricant is provided with your new unit.
Unscrew the upper part of the filter housing counter clockwise and remove the whole
pump handle. (Figure 11) Clean excess buildup from black rubber oring on bottom of
handle. Place a small amount of silicone lubricant all the way around the oring. Re
assemble.
3) If unit pumps easily, but no water flow:
Make sure prefilter is submerged.
Make sure that input hose is not blocked or pinched.
Hold the filter vertically until water flows.
The membrane on the lid of the carbon cartridge could be clogged. Remove or clean car
bon cartridge (see below) to restore flow.
4) Carbon Cartidge: Remove dirt particles on the lid of the cartridge by swirling it around
in water or by rinsing. For a more thorough cleaning, gently brush with an old toothbrush
or the green cleaning pad provided.
Attention:
Don’t use pressure, otherwise the membrane could tear.
5) Prefilter: Rinse the prefilter in water to remove any particles that may be caught in the
strainer.
6) Storage: Your Katadyn water system comes with a carry bag for storage. To prevent the
possibility of cross contamination the input hose should not contact the output barb.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Katadyn Combi Water Microfilter at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Katadyn Combi Water Microfilter in the language / languages: English as an attachment in your email.

The manual is 0,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Katadyn Combi Water Microfilter

Katadyn Combi Water Microfilter User Manual - German - 10 pages

Katadyn Combi Water Microfilter User Manual - Dutch - 10 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info