500857
32
Zoom out
Zoom in
Previous page
1/45
Next page
30
- after use;
In addition, wait until the high pressure cleaner has completely cooled down
before cleaning or maintenance.
During use, do not lock the lever (9) on the cleaner gun in the open position.
Do not remove the plug from the power outlet by pulling on the power supply
cable.
Do not put any reducers or adaptors between the electric plug and the power
outlet.
Keep the power supply cable, any extension cords, the plugs and the outlets
dry. Do not touch them with wet hands.
If the supply cord is damaged, it must be replaced by the Manufacturer or by
a Skilled Technician, in order to avoid a hazard.
Do not cover the high pressure cleaner during operation and do not place it
where there is inadequate ventilation.
When the high pressure cleaner is used in enclosed spaces, make sure that
there is adequate ventilation.
5.1 Preliminary Procedures
Unroll the high-pressure pipe (7) completely.
Attach a supply pipe to the water inlet’s quick connection (14) using a normal
garden connector.
Open the tap to the water supply and make sure that there are no drips.
Make sure that the main switch (1) is in the off position (the «0» position) and
put the plug into the electric current outlet.
Turn the main switch (1) to position «1».
Press the cleaner gun’s control lever (9) and wait for a continuous jet of water
to be issued.
Turn the main switch (1) to position «0» and connect the lance pipe (11)) to the
cleaner gun (8).
5.2 Standard Operation (high pressure)
Make sure that the nozzle head (12) is not in the position for supplying
detergent (also see the «Use with detergents» section).
Restart the high pressure cleaner by turning the main switch (1) to position «1»
and check that the spray from the nozzle is uniform, without dripping.
Note: during this restart phase, the high pressure cleaner will immediately stop
operating after the initial peak, as the Total Stop device will take effect.
Use the cleaner gun’s lever (9) to start operation of the high pressure cleaner
and thus start cleaning.
The pressure value can be read on the pressure indicator (3).
32


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karomat 595H - 66205 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karomat 595H - 66205 in the language / languages: English, Spanish as an attachment in your email.

The manual is 1,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info