657271
11
Zoom out
Zoom in
Previous page
1/130
Next page
– 3
The pump is maintenace-free.
CAUTION
In order to prevent accidents or injuries, keep in mind
the weight of the appliance during transport (see Spec-
ifications).
Lift and carry the pump on the carrying handle.
If you want to transport the appliance on a vehicle
secure it from slipping.
CAUTION
In order to prevent accidents or injuries, keep in mind
the weight of the appliance when selecting a storage lo-
cation for it (see Specifications).
Completely drain the pump and allow it to dry.
Store the pump in a frost-free place.
Maintenance
Transport
Storage
Storing the pump
Special accessories
2.997-100.0 Braided hose set Flexible 1 1/4“ braided hose with hose clamp (30 - 40 mm) with wing
screw for a connection without tools.
Especially recommendable for the immersion pumps when remov-
ing large water quantities.
Max. operating pressure: 5 bar
2.997-201.0 Prefilter for immersion pump,
small
The robust prefilter is easy to attach and protects your immersion
pump, which increases the functional reliability.
6.997-359.0 Pump connection G1 (33.3
mm) incl. Check valve
For pumps with G1 (33.3 mm) connection thread and 3/4" as well as
1" hoses, including union nut, hose clamp, flat packing and check
valve.
6.997-347.0 Spiral hose, by the meter,
25 m, 3/4"
By the meter for cutting hoses to individual lengths.
6.997-346.0 Spiral hose, by the meter,
25 m, 1"
By the meter for cutting hoses to individual lengths.
2.645-142.0 Hose PrimoFlex, 25 m, 3/4" Phthalate-free 3/4" garden hose for draining away the water.
2.645-247.0 Hose PrimoFlex, 50 m, 1" Phthalate-free 1" garden hose for draining away the water.
Troubleshooting
DANGER
Risk of mortal danger on account of electric shock!
To avoid risks, all repairs and replacement of spare parts may only be carried out by the authorised customer service
personnel.
Fault Cause Remedy
Pump runs but does not transport Air in the pump Unplug and plug in the mains plug of
the pump repeatedly until the fluid is
drawn
Suction area blocked Pull out the mains plug and clean the
suction area
(only in manual mode) Water level be-
low the minimum water level
Immerse, whenever possible, the pump
deeper into the feed fluid or proceed as
described in Chapter Operation.
Pump does not run or suddenly comes
to a standstill during operations
Power supply interrupted Check fuses and electrical connections
Thermal protection switch has
switched off the pump due to over-
heating
Pull out the mains plug, let the pump
cool down, clean the suction area,
prevent dry running
Dirt particles have got jammed into the
suction area
Pull out the mains plug and clean the
suction area
The float switch stops the pump Check position of float switch.
Pumping capacity is reducing Suction area blocked Pull out the mains plug and clean the
suction area
Pumping capacity too low The pumping capacity depends on the
flow height, hose diameter and hose
length.
Observe the maximum delivery
height, see technical data. If neces-
sary, use a larger hose diameter or a
shorter hose length.
Quick-Connect cannot be opened or
closed.
Soiling in the plug system. Remove and clean clip.
11EN
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher SP 2 Flat at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher SP 2 Flat in the language / languages: All languages as an attachment in your email.

The manual is 4,42 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info