1 Screw the G 1 ½ pump connecting piece onto the
connection nozzle.
Illustration B
2 Push the hose clamp onto the hose.
3 Push the hose onto the G 1 ½ pump connecting
piece and fasten it with a hose clamp.
4 Push the connection nozzle into the Quick-Connect.
Illustration C
Connecting a hose to the pump when using a ¾ or
1 hose:
1 Screw the G 1 threaded connection onto the con-
nection nozzle.
Illustration B
2 Fit the special accessory G 1 pump connecting
piece(6.997-359.0 pump connecting piece G 1
(33.3 mm) incl. check valve - not included in the
scope of delivery) onto the G 1 threaded connec-
tion:
a Place the check valve on the G 1 threaded con-
nection so that the lettering "UP" is legible.
b Screw the pump connecting piece G 1 onto the
G 1 threaded connection.
3 Push the hose clamp onto the hose.
4 Push the hose onto the pump connecting piece G 1
and fasten it with a hose clamp.
5 Push the connection nozzle into the Quick-Connect.
Illustration C
Erecting/immersing the pump:
1 Insert the height adjustment of the float switch into
the lock.
Illustration D
2 Place the pump securely on solid ground in the
pumped liquid or immerse it via a rope attached to
the carrying handle.
Note
The suction area must not be blocked by soiling. If the
ground is muddy, place the pump on a brick or similar.
Make sure that the pump stands level. Do not carry the
pump using the cable or hose.
Operation
DANGER
Danger of death from electric shock.
Danger of death from electric shock if live parts are
touched.
During operation, do not touch the rope attached to the
carrying handle or any objects that are in contact with
the pumped liquid (e.g. pipelines protruding into the
pumped liquid, railings) and do not reach into the
pumped liquid.
Automatic venting device
1. If the fluid level is low, any sucked-in air, or air pres-
ent in the pump, may escape via the automatic vent-
ing device. Liquid can also leak along with air.
If the pump has problems priming when the fluid lev-
el is low, unplug and plug in the mains plug repeat-
edly to assist the priming process.
Illustration E
Adjusting the filter basket
The filter basket can be operated in 2 positions.
Illustration F
1. Put the pump on the ground.
2. Clamp the pump between your feet and take hold of
the carrying handle.
3. Unlatch the filter basket by turning the handle to the
right.
4. Move the filter basket into the required position.
5. Lock the filter basket in place by turning the handle
to the left
Automatic mode
1. Set the float switch using the height adjustment, and
the cable length between the float switch and the
lock.
Note
When the pump is operated unattended, always set the
float switch to the uppermost position in order to ensure
that the pump can switch off reliably.
Illustration G
When the float switch is set to the lowermost position,
set the cable length between the float switch and the
lock to 2.5 cm, see marking on the cable.
Illustration H
2. Move the filter basket into the "Waste water and
clear water delivery" position, see chapter Adjusting
the filter basket.
3. Plug the mains plug into the socket.
Note
In automatic mode, the float switch controls the pump-
ing process automatically. The pump switches on as
soon as the float switch reaches the switch-on height
caused by the rising fluid level.
The pump switches off when the float switch reaches
the switch-off height caused by the sinking fluid level.
The float switch must be able to move freely.
Note
The switching heights vary depending on:
Position of the float switch.
Cable length between the float switch and lock.
The cable length must be at least 2.5 cm. We would
recommend retaining the set cable length. For infor-
mation on the switching heights, see chapter Spec-
ifications.
Manual operation
Note
In manual operation, the pump stays switched on.
The specified residual liquid level (see chapter Specifi-
cations) can only be achieved via manual operation.
1. Fasten the float switch in the lock pointing upwards.
Illustration I
2. Move the filter basket to the desired position de-
pending on the fluid level (see chapters Specifica-
tions and Adjusting the filter basket).
Waste water and clear water delivery.
We would recommend this filter basket po-
sition at the start of the pumping process,
since on this occasion the pumping capaci-
ty is at its greatest.
Flat vacuuming.
In this filter basket position, flat vacuuming
is possible up to 1 mm residual fluid height
in manual operation.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher SP 16.000 Dual at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher SP 16.000 Dual in the language / languages: All languages as an attachment in your email.

The manual is 4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info