803799
11
Zoom out
Zoom in
Previous page
1/148
Next page
English 11
Note
The pump can pump up to a residual fluid height of 25
mm (SP 9.500 Dirt and SP 11.000 Dirt) or 1 mm (SP
9.000 Flat).
The specified residual fluid heights are only achieved in
manual operation.
The float switch must be able to move freely.
1. Fold in the feet, see chapter Initial startup (SP 9.000
Flat).
Note
By folding in the feet, flat suction of the fluid up to 1 mm
residual fluid height is possible in manual operation.
2. Fasten the float switch in the lock so it points up-
wards.
Illustration G
ATTENTION
Risk of damage from dry running!
Dry running leads to increased wear on the pump.
Do not leave the pump unattended in manual operation.
In case of dry running, immediately pull the mains plug
out of the socket.
3. Plug the mains plug into a mains socket.
Finishing operation
1. Pull the mains plug out of the socket.
The device stops.
ATTENTION
Risk of damage!
Risk of damage due to dried soiling or additives.
Rinse and clean the device immediately after each use.
2. If dirty liquids or liquids with additives have been
pumped, rinse and clean the device immediately af-
ter finishing operation, see chapter Rinsing and
cleaning.
3. Drain the device and accessories and let them dry.
Care and maintenance
DANGER
Risk of electric shock and risk of injury!
The device contains electrical and mechanical compo-
nents.
Cleaning and user maintenance may not be carried out
by children.
Rinsing and cleaning
ATTENTION
Risk of damage!
Risk of damage due to dried soiling or additives.
Rinse and clean the device immediately after each use.
1 If dirty liquids or liquids with additives have been
pumped, the device must be rinsed afterwards: Use
the device to pump clear fresh water without addi-
tives until all soiling or additives have been flushed
out of the device.
DANGER
Risk of electric shock and risk of injury!
The device contains electrical and mechanical compo-
nents.
Always disconnect the device from the power supply
before assembling, disassembling or cleaning.
2 Pull the mains plug out of the socket.
3 Press the Quick-Connect button and remove the
connection nozzle.
Illustration C
4 Where necessary, remove residue from the hose
and on Quick-Connect.
5 Clean the outside of the device with a soft, clean
cloth and clear fresh water.
6 Drain the device and accessories and let them dry.
Service
The device is maintenance-free.
Transport
Manual transport
CAUTION
Risk of injury from tripping!
There is a risk of injury from tripping on loose cables and
hoses.
Be careful of cables and hoses when moving the device.
1. Lift and carry the device by the carrying handle.
Transport in vehicles
WARNING
Risk of injury, risk of damage!
Note the weight of the device during transport.
Store or secure the device in accordance with applica-
ble guidelines so that it cannot slip or be thrown around
during transport.
2. When transporting the device in vehicles, secure it
to prevent it from slipping or overturning in accord-
ance with the respectively applicable guidelines.
Storage
ATTENTION
Risk of damage due to frost!
An incompletely emptied device can be damaged by
frost.
Completely empty the device and accessories before
storing them.
Protect the device from frost.
Store the device in a frost-free place and not outdoors.
CAUTION
Risk of injury and damage!
The device may tip over on sloping surfaces.
Be aware of the weight of the device during storage.
1. Completely empty the pump and accessories.
2. Allow the pump and accessories to dry out.
3. Store the pump in a frost-protected place.
Troubleshooting guide
Malfunctions often have simple causes that you can
remedy yourself using the following overview. When in
doubt, or in the case of malfunctions not mentioned
here, please contact your authorised Customer Service.
Fault Cause Rectification
Pump is running, but not
delivering
Air is in the pump. 1. Check for correct startup (see chapter
Initial startup and Operation).
Dirt particles block the suction area. 1. Pull the mains plug out of the socket.
2. Clean the suction area.
The fluid level is too low (manual opera-
tion), see chapter Technical data.
1. Immerse the pump deeper into the feed flu-
id, see chapter Manual operation.
11


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher SP 11.000 Dirt at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher SP 11.000 Dirt in the language / languages: All languages as an attachment in your email.

The manual is 4.58 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info