Care and service
Descaling the steam boiler
Note
Descaling the steam boiler is not required if commer-
cially available distilled water is used.
Note
Since the lime becomes caked on the appliance, we
recommend descaling the appliance as specified in the
table (BF=boiler fillings) based on the number of times
the steam boiler is filled.
Note
Your water board or municipal utilities authority can pro-
vide information on hardness of tap water.
ATTENTION
Damaged surfaces
The descaler may corrode sensitive surfaces.
Fill and empty the appliance carefully.
1. Switch off the appliance, see Chapter .
2. Allow the appliance to cool down.
3. Unscrew the safety lock.
4. Drain the water completely out of the steam boiler.
Illustration Q
ATTENTION
Appliance damage due to descaler
An unsuitable descaler and incorrect dosing of the des-
caler may damage the appliance.
Only use KÄRCHER descaler.
Use 2 dosing units of the descaler for 1.0 l of water.
5. Apply descaler solution to the descaler according to
the details.
6. Fill the descaler solution into the steam boiler. Do
not seal the steam boiler.
7. Allow the descaler solution to take effect for
approx. 8 hours.
8. Drain descaler solution completely out of the steam
boiler.
9. Repeat the descaling process if necessary.
10. Rinse the steam boiler 2-3 times with cold water in
order to drain all the descaler solution residue.
11. Drain the water completely out of the steam boiler.
Illustration Q
Care of accessories
(Accessories - depending on scope of delivery)
Note
The micro fibre cloths are not suitable for dryer.
Note
When washing the cloths, observe the instructions on
the washing tag. Do not use any liquid softeners as this
will affect the ability of the cloths to pick up dirt.
1. Wash the floor cleaning cloths and covers at a max.
temperature of 60 °C in the washing machine.
Troubleshooting guide
Malfunctions often have simple causes that you can
remedy yourself using the following overview. When in
doubt, or in the case of malfunctions not mentioned
here, please contact your authorised Customer Service.
WARNING
Risk of electric shock and burns
Trying to eliminate faults while the appliance is connect-
ed to the mains or has not yet cooled down is always
dangerous.
Remove the mains plug.
Allow the appliance to cool down.
The steam boiler is scaled.
Descale the steam boiler
No steam
No water in the steam boiler
Refill water, see Chapter Refilling water.
The steam lever cannot be pressed
The steam lever is locked with the child lock.
Set the child lock (selector switch for steam volume)
to the front.
The steam lever is released.
Long heating-up time
The steam boiler is scaled.
Descale the steam boiler.
High water egress
The steam boiler is too full.
Press the steam gun until a little water comes out.
High water output
The steam boiler is scaled.
Descale the steam boiler.
Technical data
Subject to technical modifications.
Hardness range °dH mmol/l KF
I soft 0-7 0-1.3 55
II Medium 7-14 1.3-2.5 45
III Hard 14-21 2.5-3.8 35
IV Very hard >21 >3.8 25
Electrical connection
Voltage V 220-240
Phase ~ 1
Frequency Hz 50-60
Protection class IPX4
Protection category I
Performance data
Heating capacity W 1500
Maximum operating pressure MPa 0.32
Heating-up time Minutes 6.5
Continuous steaming g/min 40
Maximum steam blast g/min 100
Filling quantity
Steam boiler l 1.0
Dimensions and weights
Weight (without accessories) kg 3.1
Length mm 380
Width mm 254
Height mm 260
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher SC 2 EasyFix Premium Plus at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher SC 2 EasyFix Premium Plus in the language / languages: All languages as an attachment in your email.

The manual is 7,92 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info