478388
15
Zoom out
Zoom in
Previous page
1/42
Next page
K 3001 English
11
Technical specifications
Power supply 230 V
1~ 50/60 Hz
Mains fuse (slow) 10 A
Power (suction turbine) P
max
1400 Watt
P
nom
1200 Watt
Air flow 78 L/s
Vacuum 190 mbar
Capacity, wet vacuuming 11 L
Capacity, filter bag 12 L
Spraying rate 1 L/min
Capacity, fresh water 5 L
Capacity, dirty water 6 L
Length 370 mm
Width 290 mm
Height 470 mm
Weight approx. 7 kg
Size of accessory connection 35/60 mm
Sound pressure level 72 dB(A)
Protection class II
Mains cable:
Length 5 m
Type H 05 VV – F 2x1
Circuit diagram
M1 Suction turbine
S1 Turbine switch
S2 Water level cut-out
M2 Water pump
S3 Water pump switch
C Interference
suppression capacitor
D Diode
X1 Plug
H Warning light - pump
ON
When you have been using the unit for wet
vacuuming:
Empty dirt box, and rinse and dry if required.
If you have vacuumed up sticky liquids:
Rinse out accessories.
Place accessories in holder on cleaner.
Wind mains cable and spraying and suction
hose into coils, and wrap them round
accessories.
Note: To release the coupling unit of the spraying and
suction hose, press the two housing parts together
and remove the coupling.
Alfred Kärcher GmbH & Co.
Cleaning Systems
Alfred-Kärcher-Str. 28–40
P.O. Box 160
D-71349 Winnenden
Tel.: ++ 49 71 95 14-0
Fax: ++ 49 71 95 22 12
Alfred Kärcher Kommanditgesellschaft. Sitz Winnenden.
Registergericht: Waiblingen, HRA 169.
Persönlich haftende Gesellschafterin: Kärcher Reinigungstechnik
GmbH.
Sitz Winnenden, 2404 Registergericht Waiblingen, HRB
Geschäftsführer:
Johannes Kärcher, Roland Kamm, Roland Deibler, Dr. Bernhard Graf
Dr. B. Graf H. Jenner
S. Reiser
EU Declaration of Conformity
We hereby declare that the equipment described below conforms to
the relevant fundamental safety and health requirements of the
appropriate EU Directives, both in its basic design and construction
as well as in the version marketed by us.
This declaration will cease to be valid if any modifications are made
to the machine without our express approval.
Product: Spray extraction unit
Model: 1.080-xxx
Relevant EU Directives:
EU Machinery Directive (98/37/EEC)
EU Low-Voltage Equipment Directive (73/23/EEC), amended by
93/68/EEC.
EU Directive on Electromagnetic Compatibility (89/336/EEC),
amended by 91/263/EEC, 92/31/EEC, 93/68/EEC.
Harmonised standards applied:
DIN EN 60 335-1 DIN EN 61 000-3-3: 1995
DIN EN 60 335-2-10 DIN EN 55 104: 1995
DIN EN 61 000-3-2: 1995 DIN EN 55 014: 1993
National standards applied:
Appropriate internal measures have been taken to ensure that
series-production units conform at all times to the requirements of
current
EU Directives and relevant standards.
The signatories are empowered to represent and act on behalf of the
company management.
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher K3001 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher K3001 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 0,81 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info