20 English
Check setting at the spray lance.
Remove air from appliance before oper-
ation.
Switch on the appliance without con-
nection the HP hose (max. 2 minutes)
and run it until the water discharging
from the HP outlet is free of bubbles.
Switch off appliance and reconnect HP
hose.
Check the water supply.
Pull out the sieve in the water connec-
tion using flat-nose pliers and clean un-
der running water.
Cause: Voltage reduction due to weak
mains supply or when using an extension
cable.
When switching on, first pull the lever of
the trigger gun and then switch the ap-
pliance switch to "I/ON".
Clean high-pressure nozzle: Remove
dirt and debris from the nozzle bore, us-
ing a needle and rinse through with wa-
ter from the front.
Check water flow quantity.
Slight leakage from the appliance pump
is normal. If the leakage increases con-
tact the authorized customer service.
Use spray lance with pressure regula-
tion (Vario Power).
Turn the spray lance to "Mix" position.
Check the settings at the dosage regu-
lator for detergent.
Check the detergent suction hose for
kinks.
Subject to technical modifications!
Pressure does not build up in the appli-
ance
Appliance does not start, motor hums
Strong pressure fluctuations
Appliance is leaking
No detergent infeed
Technical specifications
Power connection
Voltage
1~60 Hz
220 V
Connected load 2,1 kW
Mains fuse (slow-blow) 10 A
Protective class I
Protection class IP X5
Water connection
Max. feed temperature 40 °C
Min. feed volume 10 I/min
Max. feed pressure 0,8 MPa
Max. Suction height 0,5 m
Performance data
Working pressure 12,5 MPa
Max. permissible pressure 14 MPa
Water flow rate 7,5 I/min
Detergent flow rate 0 - 0,3 I/min
Weight, ready to operate with
accessories
15,3 kg