Pulling the device
1. Pull the transport handle out until it audibly latches
into place.
2. Pull the device via the transport handle.
Transporting the device in a vehicle
1. Drain the detergent tank.
2. Secure the device against slipping and tipping over.
Storage
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during storage.
Storing the device
1. Place the device on a level surface.
2. Disconnect the spray lance from the high-pressure
gun.
3. Press the separation button on the high-pressure
gun and disconnect the high-pressure hose from the
high-pressure gun.
ATTENTION
Damage to the high-pressure hose
Damage to the high-pressure hose through incorrect di-
rection of rotation
Observe the correct direction of rotation of the hose reel
when winding on the hose.
4. Use the crank handle to turn the hose reel anticlock-
wise and coil up the high-pressure hose.
5. Store the mains connection cable and accessories
on the device.
Observe the additional notes before storing the device
for a long period of time, see chapter Care and service.
Frost protection
ATTENTION
Danger of frost
Incompletely emptied devices can be destroyed by frost.
Completely empty the device and accessories.
Protect the device from frost.
The following requirements must be satisfied:
The device is disconnected from the water supply.
The high-pressure gun is disconnected from the
high-pressure hose.
1. Switch the device on "I/ON".
2. Wait for a maximum of 1 minute until no more water
escapes from the high-pressure hose.
3. Switch off the device.
4. Store the device in a frost-protected room, together
with all accessories.
Care and service
DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
The device is maintenance-free, i.e. you do not need to
perform any maintenance work.
Clean the sieve in the water connection
ATTENTION
Damaged sieve in the water connection
Damage to the device through contaminated water
Check the sieve for damage before inserting it in the wa-
ter connection.
If necessary, clean the sieve in the water connection.
1. Remove the water connection coupling.
2. Pull the sieve out using flat pliers.
3. Clean the sieve under running water.
Illustration L
4. Insert the sieve into the water connection.
Clean the detergent filter
Clean the detergent filter before longer periods of stor-
age.
1. Pull the filter off the detergent suction hose.
2. Clean the filter under running water.
Illustration M
Troubleshooting guide
Malfunctions often have simple causes that you can
remedy yourself using the following overview. When in
doubt, or in the case of malfunctions not mentioned
here, please contact your authorised Customer Service.
DANGER
Danger of electric shock
Injuries due to touching live parts
Switch off the device.
Remove the mains plug.
Device not running
1. Press the lever of the high-pressure gun.
The device switches on.
2. Check that the voltage specified on the type plate
corresponds to the voltage of the power source.
3. Check the mains connection cable for damage.
Device does not reach required pressure
The water supply is too low
1. Open the water tap fully.
2. Check the water inlet for an adequate flow rate.
The sieve in the water connection is dirty.
1. Pull the sieve in the water connection out using flat
pliers.
2. Clean the sieve under running water.
Air is in the device.
1. Vent the device:
a Switch on the device without a connected spray
lance for a maximum of 2 minutes.
b Press the high-pressure gun and wait until the
water escaping from the high-pressure gun is
free of air bubbles.
c Connect the spray lance.
Strong pressure fluctuations
1. Clean the high-pressure nozzle:
a Use a needle to remove dirt from the nozzle drill.
b Rinse the high-pressure nozzle from the front
with water.
2. Check the water supply volume.
Device leaking
1. The device leaks a small amount for technical rea-
sons. If the leak is severe, request authorised Cus-
tomer Service.
Detergent is not sucked in
1. Use the Vario Power spray lance and turn it to "MIX".
2. Clean the filter on the detergent suction hose.
3. Check the detergent suction hose for kinks.
Warranty
The warranty conditions issued by our relevant sales
company apply in all countries. We shall remedy possi-
ble malfunctions on your appliance within the warranty
period free of cost, provided that a material or manufac-
turing defect is the cause. In a warranty case, please
contact your dealer (with the purchase receipt) or the
next authorised customer service site.
(See overleaf for the address)
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher K 3 Premium Power Control at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher K 3 Premium Power Control in the language / languages: All languages as an attachment in your email.

The manual is 8.32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info