804670
20
Zoom out
Zoom in
Previous page
1/260
Next page
20 English
free of cost, provided that a material or
manufacturing defect is the cause. In a war-
ranty case, please contact your dealer (with
the purchase receipt) or the next author-
ised customer service site.
(See overleaf for the address)
Technical data
Subject to technical modifications.
IVS 100/55 M Z22 IVS 100/75 M Z22
Electrical connection
Mains voltage V 400 400
Power frequency Hz 3~ 50 3~ 50
Degree of protection IP 65 IP 65
Protection class I I
Maximum permissible mains grid im-
pedance
Ω0.156+j0.098 0.400+j0.250
Nominal power W 5500 7500
Power input (normal operation) W 6220 6080
Fuse protection A 16 32
Characteristic of the fuse C B/C
Dimensions and weights
Typical operating weight kg 157 174
Length x width x height mm 1202x686x1495 1202x686x1495
Cable length m 8,2 8,2
Nominal width of the suction hose NW DN72 NW DN72
Ambient conditions
Storage temperature °C -10 ... +40 -10 ... +40
Relative humidity % 30-90 30-90
Device performance data
Tank content l 100 100
Air quantity (max.) m3/h 353 373
Vacuum (max.) kPa (mbar) 23,5 30,5
Filter area m222
Determined values in acc. with EN 60335-2-69
Hand-arm vibration value m/s2<2,5 <2,5
Sound pressure level dB(A) 77 73
Uncertainty K dB(A) 2 2
Surface temperature (max.) °C 125,0 125,0
Ignition protection class II 3D EX tc IIIC
T125 °C Dc
II 3D EX tc IIIC
T125 °C Dc
Mains cable
H07BQ-F mm25 x 2,5 5 x 2,5
Part number (EU) 9.988-768.0 9.988-767.0
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher IVS 100-75 M Z22 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher IVS 100-75 M Z22 in the language / languages: All languages as an attachment in your email.

The manual is 9.82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info