804632
16
Zoom out
Zoom in
Previous page
1/194
Next page
16 English
4. Dispose of or reuse the contents in ac-
cordance with statutory regulations.
Emptying the liquid container by
tilting
See graphics page for illustrations
1. Switch the device off and disconnect it
from the power supply.
2. Move the device to the waste water tank.
3. Take the drum pump out of the stand
pipe.
Illustration F
4. Remove the suction head (see chapter
Removing the suction head).
5. Remove all accessory parts.
6. Prepare the liquid container for empty-
ing:
Using the tilting device Tc (Device
with tilting device Tc)
a Open the lock of the liquid container.
IVR-L 120/24-2
Illustration G
IVR-L 100/24-2
Illustration H
using the crane grommet (Device
without tilting device Tc)
a Lift the device onto the crane grommet
(see chapter Device description) us-
ing suitable lifting gear.
DANGER
Failure to observe the weight
Risk of injury from falling device
Observe the applicable accident prevention
guidelines and safety instructions.
Every time before lifting, check to ensure
correct functioning of the lifting device.
Only lift the device via the provided crane
grommet.
Ensure that there will be no unintentional
unhooking of the lifted load.
The crane may exclusively be operated by
qualified staff.
No people may be located within the haz-
ard zone of the crane.
Do not leave the device hanging unattend-
ed on the crane.
7. Tip the container with the push handle.
Illustration I
8. Dispose of or reuse the contents in ac-
cordance with statutory regulations.
9. Fit and lock the suction head.
Emptying the liquid container using
the drum pump
See graphics page for illustration
Note
Secure the disposal hose in the holder
when not in use.
Illustration J
1. Only when emptying after vacuuming
operations:
a Switch the device off and disconnect it
from the power supply.
b Move the device to the waste water
tank.
2. Connect the disposal hose to the waste
water tank.
3. Plug in the mains plug of the drum
pump.
4. Switch the drum pump on at the on/off
switch.
Note
Avoid dry running the drum pump.
Do not leave the drum pump unattended.
5. Adjust the flow rate with the +/- button.
Note
Only when emptying during vacuuming
operations:
Select the flow rate according to the vacu-
umed amount.
6. Dispose of or reuse the contents in ac-
cordance with statutory regulations.
Cleaning the liquid container
See graphics page for illustrations
Note
Bacterial contamination may occur through
the use of water-based cooling lubricants.
Wear suitable protective clothing when re-
moving deposits.
1. Empty the container.
2. Remove deposits in the container.
3. Dispose of the deposits in accordance
with the applicable regulations.
4. Remove chippings and deposits from
the support plates.
Illustration K
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher IVR-L 120-24-2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher IVR-L 120-24-2 in the language / languages: All languages as an attachment in your email.

The manual is 7.78 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info