Technische Daten
HDS 9/16-4 ST
Gas
HDS 12/14-4 ST
Gas
HDS 12/14-4 ST
Gas LPG
1.251-900 1.251-901 1.251-902
Leistungsdaten
Arbeitsdruck Wasser (mit Standarddüse) MPa (bar) 16 (160) 14 (140) 14 (140)
Max. Betriebsüberdruck (Sicherheitsventil) MPa (bar) 18,5 (185) 18,5 (185) 18,5 (185)
Fördermenge Wasser (stufenlos regelbar) l/h (l/min) 500-1000 (8,3-
16,6)
600-1200 (10-20) 600-1200 (10-20)
Reinigungsmittelansaugung (stufenlos regelbar) l/h (l/min) 0-50 (0-0,8) 0-60 (0-1) 0-60 (0-1)
Wasseranschluss
Zulaufmenge (min.) l/h (l/min) 1100 (18,3) 1300 (21,7) 1300 (21,7)
Zulaufdruck (min.) MPa (bar) 0,1 (1) 0,1 (1) 0,1 (1)
Zulaufdruck (max.) MPa (bar) 0,6 (6) 0,6 (6) 0,6 (6)
Elektrischer Anschluss
Stromart -- 3N~ 3N~ 3N~
Frequenz Hz 50 50 50
Spannung V 380-420 380-420 380-420
Anschlussleistung kW 6,4 7,5 7,5
Elektrische Absicherung (träge) A 16 20 20
Schutzart -- IPX5 IPX5 IPX5
Schutzklasse -- I I I
Maximal zulässige Netzimpedanz Ohm (0,381+j 0,238) -- --
Elektrozuleitung mm25 x 2,5 5 x 2,5 5 x 2,5
Temperatur
Zulauftemperatur (max.) °C 30 30 30
Max. Arbeitstemperatur Heißwasser °C 98 98 98
Max. Temperatur Sicherheitsthermostat °C 110 110 110
Temperaturerhöhung bei max. Wasserdurchsatz °C 60-65 60-65 60-65
Heizleistung netto (Hi) kW 70 95 95
Kaminzug kPa 0,01-0,04 0,01-0,04 0,01-0,04
Gas-Anschlusswerte
Erdgas E (G 20) m3/h 7,2 9,8 --
Erdgas LL (G 25) m3/h 8,2 11,4 --
Nennanschlussdruck (Erdgas) kPa 1,8-5 1,8-5 --
Propan kg/h -- -- 7,2
Nennanschlussdruck (Propan) kPa -- -- 5-6
Umweltdaten
Normnutzungsgrad % 97 97 97
Normemissionsfaktor NOX (Erdgas G 25) mg/kWh < 40 < 40 --
Normemissionsfaktor CO (Erdgas G 25) mg/kWh < 40 < 40 --
Werte zur Schornsteinbemessung
Überdruckeignung (min.) kPa 0,05 0,05 0,05
Zugbedarf kPa 0 0 0
Abgasmassenstrom - Volllast kg/h 130 166 166
CO2 (Erdgas) % 9,5 9,5 --
CO2 (Propan) % -- -- 12
Abgastemperatur max./min. °C 190/150 170/130 170/130
Verbrennungsluft/Luftzufuhr Max. Länge: 10 m mit zwei 90° Bögen (Mindestdurchmesser 100 mm).
Nach örtlichen Vorschriften aus dem Aufstellungsraum oder Frischluft
von außen.
Kondensatablass
Kondensatablass (max.) l/h 4 (über Siphon in
Kanalisation)
4 (über Siphon in
Kanalisation)
4 (über Siphon in
Kanalisation)
Anschluss DN 40 (HTR) 40 (HTR) 40 (HTR)
Minimale Wassersäule, Siphon mm 300 300 300
Geräte-Kategorie Europa -- I 2E (r), I 2ELL, I
2H, I 2L, I2 HE
I 2E (r), I 2ELL, I
2H, I 2L, I2 HE
I 3P
9DE
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher HDS 9-16-4 ST Gas at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher HDS 9-16-4 ST Gas in the language / languages: All languages as an attachment in your email.

The manual is 31,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info