726290
36
Zoom out
Zoom in
Previous page
1/524
Next page
- 15
DANGER
Risk of explosion! Only refill diesel oil or light fuel oil. Unsuitable
fuels, e.g. petrol, are not to be used.
Refill fuel tank.
ATTENTION
Hot water operations without fuel will cause damage to the fuel
pump. Ensure adequate fuel supply before starting hot water op-
erations.
Figure 3 - Pos. 14
Note: The EASY!Lock system joins components with a quick-fas-
ten thread solidly and securely with just one turn.
Connect the high pressure hose with the hand-spray gun and
the spray pipe and connect it to the high pressure outlet of the
appliance or the high pressure pipe network.
Fasten the nozzle mouth-piece (b) with the union nut (a) on
the spray pipe (d). Please ensure that the sealing ring (c) is
cleanly positioned in the nut.
Remove spring (c) from the lid support (b) of the softener tank
(a).
Fill the tank with Kaercher softener liquid RM 110 (Order no.
2.780-001).
DANGER
Dangerous electrical voltage! Setting may only be done by an
electrician.
Determining the hardness of tap water:
through the public water supply works,
using a hardness tester (order no. 6.768-004)
Remove the appliance cover.
Open the switch box at the operating panel.
Set the speed potentiometer (a) according to the water hard-
ness. You can refer to the correct setting in the table.
Example:
For a water hardness of 15 °dH, set 6 on the value scale of the
speed potentiometer. This results in a pause of 31 seconds, i.e.
the solenoid valve will open briefly every 31 seconds.
The operations stand-by time is set on the larger plate on the left
side-wall of the electrical cabinet.
The operations stand-by time is set in the factory to a minimum
time of 2 minutes and can be increased to a maximum time of 8
minutes.
Measures to be taken before start-up
Anti-calcification measures
abc d
b
c
a
Water hardness (°dH) 5 10 15 20 25
Scale on the speed potenti-
ometer
87654.5
Pause (in seconds) 50 40 31 22 16
Adjusting the operations stand-by time
a
36 EN
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher HDS 12-14-4 ST at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher HDS 12-14-4 ST in the language / languages: All languages as an attachment in your email.

The manual is 17,62 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info