- 9
You can enter into a maintenance contract
with the concerned Kaercher Sales Office
for the machine.
The machine should be stored in frost-free
rooms. In case there is frosting risk, for e.g.
if the machine is installed in open areas,
then the machine must first be emptied and
flushed using an anti-freezing agent.
Screw off water supply hose and high
pressure hose.
Operate device for max. 1 minute until
the pump and conduits are empty.
Note: Observe handling instructions of the
anti-freeze agent manufacturer.
Fill in normal anti-frost agents in the
swimmer tank right until the top.
Place the collection trough under the
high pressure exit.
Switch on the appliance and let it run
until the safety mechanism against lack
of water in swimmer tank gets activated
and the machine is switched off.
A certain corrosion protection is achieved
with this as well.
DANGER
Risk of injury! The main switch is to be
switched off while carrying out any repairs
or maintenance jobs.
Error number display of the control
When an error is triggered, the opera-
tion readiness of the appliance is
switched off and the pump is shut down.
The control lamp "collection error" will
blink in the pulse of the reported error
number; or if the water level is low or the
winding protection contact is triggered
on the engine, the respective message
lamp will illuminate. In addition to this,
the error number on the 7-segment dis-
play of the control unit will be displayed.
If one of the above errors occurs, the
appliance can be restarted after the er-
ror has been corrected by activating the
release switch.
Maintenance contract
Frost protection
Drain water
Flush device with anti-freeze agent
Troubleshooting
Error
number
Error description
01 Water shortage
02 Winding protection contact
03 Water temperature is too high
04 Leakage switch-off 1 (30 min-
utes of continuous operation).
05 Leakage switch-off 2 (minor
leakage)
06 Pressure sensor does not trans-
mit signal
07 Temperature sensor does not
transmit signal
08 ON switch continuously activat-
ed
25EN
25


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher HDC 20-16 H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher HDC 20-16 H in the language / languages: All languages as an attachment in your email.

The manual is 16,13 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info