726165
19
Zoom out
Zoom in
Previous page
1/340
Next page
– 3
Quality requirements for water:
ATTENTION
Only clean water may be used as high
pressure medium. Impurities will lead to in-
creased wear and tear or formation of de-
posits in the appliance.
If recycled water is used, the following limit
values must not be exceeded.
Please follow the national rules and
regulations for fluid spray jets of the re-
spective country.
Please follow the national rules and
regulations for accident prevention of
the respective country. Fluid spray jets
must be tested regularly and the results
of these tests must be documented in
writing.
The appliance/accessories must not be
modified.
DANGER
Do not use high pressure cleaners
when there has been an oil spill; move
the appliance to another spot and avoid
any sort of spark formation.
Do not store, spill or use fuel in the vi-
cinity of open flames or appliances such
as ovens, boilers, water heaters, etc.
that have an ignition flame or can gen-
erate sparks.
Keep even mildly inflammable objects
and materials away from the muffler (at
least 2 m).
Do not start the engine without the muf-
fler; check, clean and replace, if re-
quired, the muffler at regular intervals.
Do not use the engine in forest, bushes
or grassy areas without fitting a spark
receiver at the exhaust
Except for setting jobs, do not run the en-
gine when the air filter is removed or there
is no cover over the suction support.
Do not make any adjustments to the
regulator springs, regulator bars or oth-
er parts that can bring forth an increase
in the engine speed.
Risk of burns! Do not touch hot muf-
flers, cylinders or radiator ribs.
Do not put hands or feet close to mov-
ing or rotating parts.
Risk of poisoning! The appliance should
not be operated in closed rooms.
Do not use unsuitable fuels, as they
may be dangerous.
Safety devices serve for the protection of the
user and must not be put out of operation or
bypassed with respect to their function.
If the hand spray gun is closed, the
overflow valve opens and the high pres-
sure pump diverts the water back to the
pump suction side. Thus the permissi-
ble working pressure is not exceeded.
The overflow valve is set by the manu-
facturer and sealed. Setting only by
customer service.
Please do not let mineral oil contaminated
waste water reach soil, water or the sew-
age system. Perform engine cleaning and
bottom cleaning therefore only on speci-
fied places with an oil trap.
pH value 6,5...9,5
electrical conductivity * Conductivity
fresh water
+1200 μS/cm
settleable solids ** < 0,5 mg/l
total suspended solids *** < 50 mg/l
Hydrocarbons < 20 mg/l
Chloride < 300 mg/l
Sulphate < 240 mg/l
Calcium < 200 mg/l
Total hardness < 28 °dH
< 50 °TH
< 500 ppm
(mg CaCO3/l)
Iron < 0,5 mg/l
Manganese < 0,05 mg/l
Copper < 2 mg/l
Active chloride < 0,3 mg/l
free of bad odours
* Maximum total 2000 μS/cm
** Test volume 1 l, settling time 30 min
*** no abrasive substances
Safety instructions
Safety Devices
Overflow valve
19EN
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher HD 9-21 G at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher HD 9-21 G in the language / languages: All languages as an attachment in your email.

The manual is 14,1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info