726315
19
Zoom out
Zoom in
Previous page
1/168
Next page
- 2
The winding protection contact in the motor
winding of the pump drive switches off the
engine when there is a thermal overload.
(With HD 13/12-4 ST only...).
If the appliance is not used for an extended
period of time (adjustable 5...120 minutes),
the appliance will shut off.
If the operating time (without interruption of
work) exceeds an adjustable value (5...120
minutes), the appliance will shut off.
The motor protection switch switches off
the device if the power consumption is
high.
In case of leaks in the high pressure sys-
tem, the appliance is shut off.
After the operation readiness period, a so-
lenoid valve opens in the high pressure
system and relieves the pressure.
The lack of water fuse in the float container
prevents the high pressure pump from run-
ning dry in case of a lack of water.
This equipment produces water under
high pressure downstream to high pres-
sure cleaning devices. If required the
detergent is drawn in and added to the
water.
The high pressure module is perma-
nently installed in a dry, frost-free room.
The high pressure water is distributed
through a fixed network of pipes.
Alternatively, a hand spray gun with a
high pressure hose can be connected
directly to the high pressure outlet of the
appliance.
The high pressure model must be in-
stalled at a wall in such a way that the
rear opening is sealed by the wall.
DANGER
Risk of injury! Follow the respective safety
regulations when operating at gas stations
or other dangerous areas.
ATTENTION
Only clean water may be used as high
pressure medium. Impurities will lead to in-
creased wear and tear or formation of de-
posits in the appliance.
If recycled water is used, the following limit
values must not be exceeded.
Winding protection contact
Operational readiness period
Hose break protection
Motor protection switch
Leakage monitoring
Pressure relief (option)
Lack of water fuse (option)
Proper use
Please do not let mineral oil contaminated
waste water reach soil, water or the sew-
age system. Perform engine cleaning and
bottom cleaning therefore only on speci-
fied places with an oil trap.
Water quality requirements
pH value 6,5...9,5
electrical conductivity * Conductivity
fresh water
+1200 µS/cm
settleable solids ** < 0,5 mg/l
total suspended solids *** < 50 mg/l
Hydrocarbons < 20 mg/l
Chloride < 300 mg/l
Sulphate < 240 mg/l
Calcium < 200 mg/l
Total hardness < 28 °dH
< 50 °TH
< 500 ppm
(mg CaCO3/l)
Iron < 0,5 mg/l
Manganese < 0,05 mg/l
Copper < 2 mg/l
Active chloride < 0,3 mg/l
free of bad odours
* Maximum total 2000 µS/cm
** Test volume 1 l, settling time 30 min
*** no abrasive substances
19EN
19


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher HD 9-18-4 ST at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher HD 9-18-4 ST in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 11,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info