- 7
In order to guarantee a reliable operation of
the equipment, we success, you signed a
maintenance agreement. Please refer to
your local Kärcher service department.
Who may perform maintenance?
Operator
Work designated with the sign “Opera-
tor” may only be carried out by persons
who have been instructed in the safe
operation and maintenance on the high
pressure plant.
Electricians
Only persons with a professional train-
ing in the electro-technical area.
Customer Service
Work designated with the sign “Cus-
tomer Service” may only be done by the
fitters of Kärcher Customer Service.
WARNING
Risk of burns due to hot oil or hot parts of
the plant. Allow the pump to cool down for
minutes before oil change.
Note:
Used oil must only be disposed of by the
designated collection points. Please turn in
used oil there. Polluting the environment
with used oil is prosecutable.
For oil type refer to technical specifica-
tions.
1 Oil tank
2 Oil drain screw
Place the collection trough under the oil
drain screw.
Remove the lid of the oil container.
Unscrew the oil drain screw and collect
oil.
Fix in the oil drain screw and tighten it.
Slowly fill in new oil until the "MAX"
marking on the oil container.
Attach the lid of the oil container.
Dispose of old oil ecologically or turn it
in at a collection point.
Calcium deposits can lead to:
higher pipe resistances
even to failure of the components with
heavy calcium deposits
DANGER
Risk of explosion due to combustible
gases! Smoking strictly prohibited dur-
ing decalcification. Ensure proper ven-
tilation.
Risk of chemical burns on account of
acid! Wear protective glasses and pro-
tective gloves.
Note:
Follow the specifications of the accident
prevention regulation BGV A1.
Follow instructions for use on the lable
of the decalcifying agent.
According to statutory requirements, only
tested and approved boiler decrusting
agents may be used.
RM 100 (Order No. 6.287-008) dis-
solves chalk and simple compounds of
chalk and detergents residues.
RM 101 (Order No. 6.287-013) dis-
solves the deposits that cannot be dis-
solved using RM 100.
Note:
As an anti-corrosion measure and for neu-
tralising the acid residue, we recommend
that you finally pump an alkaline solution
through the machine (for e.g. RM 81) via
the detergent tank.
First decalcify the swimmer tank.
Shut off water supply.
Remove the lid of the swimming tank.
Remove the hose from the suction site
of the pump for the swimming tank on
the pump site.
Seal the free end of the hose.
Fill in 7 percent decalcification solution.
Remove resin completely from the tank
after decalcification.
Decalcify the high pressure installation:
Remove the high pressure hose from
the network supply and hang it in the
swimmer tank.
Run the calcium dissolving acid mixture
prepared in the tank through the instal-
lation's cycle, allow it to take effect,
rinse.
Maintenance contract
Maintenance Works
Oil change
Descaling
24 EN
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher HD 13-12-4 ST-H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher HD 13-12-4 ST-H in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 11,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info