726318
20
Zoom out
Zoom in
Previous page
1/168
Next page
- 3
1 Solenoid valve water supply (upgrade
kit, optional)
2 Water inlet
3 Swimmer valve
4 Container of softener liquid
with solenoid valve (4.1), only with mod-
el ST-H (option with model ST)
5 Prepressure pump, only with model ST-H
6 High pressure pump
7 Overflow valve
8 Back up valve
9 Pressure switch
10 Detergent injector
11 Pressure relief valve (upgrade kit, op-
tion)
12 Vibration dampener
13 High-pressure outlet
14 Pipe system (option)
15 High pressure hose
16 Trigger gun
with shutoff valve (16.1) and pressure/
volume regulation (16.2)
17 High pressure nozzle (triple nozzle)
18 Backflow valve, detergent suction un-
der low pressure
19 Dosage valve for detergent
20 Level sensor detergent (upgrade kit,
optional)
consisting of 1 detergent solenoid valve
(20.1) and 1 detergent level sensor
(20.2).
21 Cleaning agent container
22 Detergent dosing 2nd detergent, (up-
grade kit, option), consisting of 1 deter-
gent dispensing valve (22.1), 1 deter-
gent solenoid valve (22.2), 1 detergent
level sensor (22.3)
23 Detergent dosing 2nd detergent under
high pressure (upgrade kit, option),
consisting of 1 detergent pump (23.1),
and 1 detergent level sensor (23.2)
24 Detergent dosing, double under high
pressure (upgrade kit, option), consist-
ing of 1 detergent dispensing valve
(24.1), 2 detergent pumps (24.2), and 2
detergent level sensor (24.3)
25 Water filter (option)
With the decrease in total water flow the
water runs through the water inlet, the
swimmer tank, advance pressure pump hot
water and through the high-pressure pump
to the high-pressure outlet.
If only a part of the water capacity fed from
the pump is needed, the rest of the flow
runs through the flow regulator back to the
suction site of the high-pressure pump.
Detergent is suctioned via the detergent in-
jector and metered using the detergent dis-
pensing valve.
In order activate the suction, the multi-noz-
zle must be set to "CHEM" (low pressure
flat jet).
With the upgrade kit "Detergent dosing in
high pressure mode (option)", detergent
can be added via a detergent pump.
If the system pressure sinks during the
standby period due to the opening of one of
the consumers, the pressure switch will
switch on the high pressure pump.
Adding liquid softener will prevent the build-
up of lime when operating with hot water.
Starting with a hardness range of "medium"
(8.4 - 14 °dH) and a supply temperature of
more than 6C, the upgrade kit for water sof-
tening (DGT) must be installed, or an exter-
nal water softening system must be pre-
sent. ST-H appliances are suitable for hot
water operation of up to 85°C; ST applianc-
es are suitable for supply water tempera-
tures of up to 70°C.
Function
Flow pattern
Full pump capacity
Parts removal
Detergent
Automatic pump start
Softener system
20 EN
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher HD 13-12-4 ST-H at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher HD 13-12-4 ST-H in the language / languages: English, German, Dutch, Danish, French, Italian, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 11,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info