725182
17
Zoom out
Zoom in
Previous page
1/296
Next page
– 2
High-pressure jets can be dan-
gerous if improperly used. The
jet may not be directed at persons, animals,
live electrical equipment or at the appliance
itself.
According to applicable regula-
tions, the appliance must never be
used on the drinking water net
without a system separator. A suit-
able system separator by KÄRCHER or al-
ternatively a system separator according to
EN 12729 type BA must be used.
Water that was flowing through a system
separator is considered non-drinkable.
CAUTION
Always connect the system separator to
the water supply, never directly to the appli-
ance!
Use this high pressure cleaner exclusively
for
Cleaning using low pressure jet and de-
tergent (for e.g. for cleaning machines,
cars, buildings, tools),
For cleaning using high pressure jet
without detergent (for e.g. for cleaning
facades, terraces, garden appliances).
For stubborn dirt, we recommend the use of
the dirt blaster as a special accessory.
Quality requirements for water:
ATTENTION
Only clean water may be used as high
pressure medium. Impurities will lead to in-
creased wear and tear or formation of de-
posits in the appliance.
If recycled water is used, the following limit
values must not be exceeded.
Safety devices serve to protect the user
and must not be rendered in operational or
their functions bypassed.
While reducing the water supply/quantity
regulation at the pump head, the overflow
valve opens and part of the water flows
back to the pump suck side.
If the pulling lever on the trigger gun is re-
leased the pressure switch turns off the
pump, the high-pressure jet is stopped. If
the pulling lever is pulled the pump is
turned on again.
The overflow valve and pressure switch are
set and sealed at the factory. Setting only
by customer service.
Symbols on the machine
Proper use
pH value 6,5...9,5
electrical conductivity * Conductivity
fresh water
+1200 µS/cm
settleable solids ** < 0,5 mg/l
total suspended solids *** < 50 mg/l
Hydrocarbons < 20 mg/l
Chloride < 300 mg/l
Sulphate < 240 mg/l
Calcium < 200 mg/l
Total hardness < 28 °dH
< 50 °TH
< 500 ppm
(mg CaCO3/l)
Iron < 0,5 mg/l
Manganese < 0,05 mg/l
Copper < 2 mg/l
Active chloride < 0,3 mg/l
free of bad odours
* Maximum total 2000 µS/cm
** Test volume 1 l, settling time 30 min
*** no abrasive substances
Safety Devices
Overflow valve with pressure switch
Environmental protection
The packaging material can be
recycled. Please do not throw
the packaging material into
household waste; please send it
for recycling.
17EN
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher HD 10-25-4 SX at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher HD 10-25-4 SX in the language / languages: All languages as an attachment in your email.

The manual is 9,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email