477855
22
Zoom out
Zoom in
Previous page
1/294
Next page
– 12
ƽ Danger
Always disconnect the mains plug and al-
low the steam cleaner to cool down before
performing any maintenance work.
Rinse the steam cleaner boiler at the latest
after 10 boiler fillings.
Î Disconnect the mains plug from the
socket.
Î Allow the steam cleaner to cool down.
Î Empty the water reservoir.
Î Remove the accessories from the ac-
cessory compartments.
Illustration
Î Open the locking door of the accessory
compartment.
Î Remove the accessories from the ac-
cessory compartment.
Î Open the maintenance lock. For this,
place the open end of an extension pipe
onto the maintenance lock, lock it into
the guide and unscrew it.
Î Fill the boiler with water and shake it
strongly. This dissolves lime scaling re-
siding on the boiler bottom.
Î Completely empty the steam boiler to
remove existing water (see Fig. ).
As limescale builds up on the boiler walls,
we recommend to descale the boiler in the
following intervals (RF=reservoir fillings):
Note: Please contact your Conservancy
Board or the local water supply company to
inquire about the hardness of your water.
Î Disconnect the mains plug from the socket.
Î Allow the steam cleaner to cool down.
Î Empty the water reservoir.
Î Remove the accessories from the ac-
cessory compartments.
Illustration
Î Open the locking door of the accessory
compartment.
Î Remove the accessories from the ac-
cessory compartment.
Î Open the maintenance lock. For this,
place the open end of an extension pipe
onto the maintenance lock, lock it into
the guide and unscrew it.
Î Completely empty the steam boiler to
remove existing water (see Fig. ).
Warning
Only use products approved by KÄRCHER
to exclude any damages of the appliance.
Î User the KÄRCHER decalcifier sticks
(order no. 6.295-047) to decalcify the
water. Please follow the dosing instruc-
tions on the packaging while using the
decalcifying solution.
Caution
Use caution when filling and emptying the
steam cleaner. The descaling solution can
have an aggressive effect on delicate sur-
faces.
Î Pour the descaling solution into the boil-
er and allow it to react for approximately
8 hours.
Warning
Do not screw the maintenance lock onto
the appliance during the decalcifying.
Do not use the steam cleaner as long as
there is decalcifying agent in the boiler.
Î Completely empty the descaling solu-
tion after 8 hours. A small amount of the
solution will remain in the boiler. There-
fore, you should rinse the boiler two to
three times with cold water to remove
any residues of the descaler.
Î Completely empty the steam boiler to
remove existing water (see Fig. ).
Î Allow the storage compartment for the
mains cable to dry.
Î Screw the maintenance lock in using
the extension pipe.
Î Fill water reservoir (see page 8).
Î The steam cleaner is ready to use.
Maintenance and care
Rinsing the steam boiler
Descaling the Steam Boiler
Degree of hard-
ness
° dH mmol/l RF
I soft 0- 7 0-1,3 100
II medium 7-14 1,3-2,5 90
III hard 14-21 2,5-3,8 75
IV very hard >21 >3,8 50
22 EN
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher CB SC 4.100 C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher CB SC 4.100 C in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Turkish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 6,76 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info