The pump capacity of the pump depends on the lifting
height, hose diameter and hose length.
1. Observe max. lifting height, see technical data, if
necessary select other hose diameter or other hose
length.
The circuit breaker of the HP pump has triggered
The current of the pump was too high.
1. Push the button on the back of the edge bracket
holder of the circuit breaker back in so that the circuit
breaker is reset.
2. Pump can be started again.
Technical data
Subject to technical modifications.
Pump characteristic curve
The possible flow rate is further increased:
The lower the suction and lifting heights are.
The greater the diameter of the hoses used is.
The shorter the hoses used.
The smaller the pressure loss caused by the con-
nected up accessories.
EU Declaration of Conformity
EU Declaration of Conformity
We hereby declare that the machine described below
complies with the relevant basic safety and health re-
quirements in the EU Directives, both in its basic design
and construction as well as in the version placed in cir-
culation by us. This declaration is invalidated by any
changes made to the machine that are not approved by
us.
Product: Pump battery
Type: BP 2.000-18
Currently applicable EU Directives
2014/35/EU
2014/30/EU
2011/65/EU
Harmonised standards used
EN 60335-1
EN 60335-2-41
EN 62233: 2008
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 2015
EN IEC 63000: 2018
The signatories act on behalf of and with the authority of
the company management.
Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 - 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2022/01/01
Declaration of Conformity (UK)
We hereby declare that the product described below
complies with the relevant provisions of the following
UK Regulations, both in its basic design and construc-
tion as well as in the version put into circulation by us.
This declaration shall cease to be valid if the product is
modified without our prior approval.
Product: Pump battery
Type: BP 2.000-18
Currently applicable UK Regulations
S.I. 2016/1101 (as amended)
S.I. 2016/1091 (as amended)
S.I. 2012/3032 (as amended)
Designated standards used
EN 60335-1
EN 60335-2-41
EN 62233: 2008
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 2015
EN IEC 63000: 2018
The signatories act on behalf of and with the authority of
the company management.
BP
2.000-18
Barrel
Electrical connection
Voltage V 18
Nominal power W 80
Device performance data
Maximum flow rate l/h 2000
Pressure (max.) MPa
(bar)
0,20
(2,0)
Delivery height (max.) m 20
Particle size (max.) of permissible
feed fluids
mm 0,5
Dimensions and weights
Weight (without accessories) kg 1,1
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher BP 2.000-18 Barrel at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher BP 2.000-18 Barrel in the language / languages: All languages as an attachment in your email.

The manual is 3.98 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email