– 4
Illustration
Adjust float switch.
The float switch can be adjusted in
order to adjust the switch-on and
switch-off height.
Reducing the distance between the
float switch and the holder results in
a higher switch-on level and a lower
switch-off level.
Leave sufficient space so that the
float switch can move freely.
Attach fastening rope (not included
in the scope of delivery) to the han-
dle.
Lower the pump on the fastening
rope into the fluid to be delivered.
Secure the fastening rope.
Illustration
The maximum immersion depth (h1)
describes the depth of the water in
which the pump can still be installed.
Usually it is not necessary to lower the
pump to the maximum immersion
depth.
The delivery height (h2) describes the
height difference between the water
level and the water outlet at the end of
the delivery hose. The maximum deliv-
ery height must be observed so that
the pump can deliver. This must be ob-
served over the entire pathway of the
pump, as the delivery height will in-
crease with the falling water level (due
to pumping).
The fluid level must be at least 5 cm for
the pump to draw independently.
Insert the mains plug into the sock-
et.
Caution
Dry running damages the pump.
Do not leave the pump unat-
tended during operation.
Alternatively use a dry run
protection or an electronic
pressure switch with dry run
protection (see optional ac-
cessories).
Disconnect the main plug from the
socket.
Danger
Risk of electric shock. Turn off
the appliance and remove the
mains plug prior to performing
any care and maintenance work.
Note:
Soiling can deposit and lead to mal-
functions.
Rinse the pump with clear water at reg-
ular intervals.
Disconnect the main plug from the
socket.
Clean the intake grille using a suita-
ble brush and rinse with clear water.
Illustration
Unscrew the connection adapter
from the connection piece.
Remove the check valve.
Screw the connection adapter into
the connection piece.
Operation
Finish operation
Cleaning
17EN
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Karcher BP 2 Cistern at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Karcher BP 2 Cistern in the language / languages: English, German, Dutch, French, Italian, Portuguese, Portuguese, Spanish as an attachment in your email.

The manual is 1,73 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info