Assembly page 6/16
Fax +32 2 359 95 50
Power switches
Lower power switch = reduced power
Upper power switch = medium power
Both power switches = full power
For easy recognition of the heating level selected at any time, the switches are equipped with
an indicator lamp.
Once a switch has been pressed to start operation, the integral thermostat will switch the unit
on and off automatically to keep the temperature at a constant level.
Thermostat and frost protection
Using the infinitely adjustable thermostat control, the unit can be preset to a specific
temperature. When the intended temperature is reached, the unit will automatically switch off.
Once the temperature has fallen below the pre-set level, the heater will switch on again.
If the thermostat is set to its * (MIN) position, the unit will switch on once the temperature has
fallen below 0°C. Depending on the size of the room make sure the heat output is sufficient to
keep the room temperature above freezing point.
Note: the metallic parts of this appliance become hot during use so if you need to move the
appliance during use, use the side handles.
OVERHEAT PROTECTION
This heater is protected with an overheat protection that switches off the appliance
automatically in case of overheat, e.g. due to the total or partial obstruction of the grids. In this
case, unplug the appliance, wait about 10 minutes for it to cool and remove the object that is
obstructing the grids. Then switch it back on. The appliance should operate normally. Should
the problem persist, please contact the nearest customer service.
CLEANING AND CARE
Before cleaning the appliance, ensure it is disconnected from the power supply and has
cooled down completely.
To avoid the risk of electric shock, do not clean the heater with water and do not immerse
it. Clean the housing with a damp cloth.
If necessary, dust particles accumulated in the air outlet openings may be removed with a
vacuum cleaner. This maintenance should be done regularly to assure the good
operation of the appliance.
PROTECTION OF THE ENVIRONMENT DIRECTIVE 2002/96/EC
In order to preserve our environment and protect human health, the waste electrical and
electronic equipment should be disposed of in accordance with specific rules with the
implication of both suppliers and users. For this reason, as indicated by the symbol on the
rating label or on the packaging, your appliance should not be disposed of as unsorted
municipal waste. The user has the right to bring it to a municipal collection point performing
waste recovery by means of reuse, recycling or use for other applications in accordance with
the directive.
6


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kalorik KA CV 9 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kalorik KA CV 9 in the language / languages: English, French, Portuguese as an attachment in your email.

The manual is 0,38 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info