The drain hose must be arranged beneath the copper pipe.
The drain hose must not be hunched or bended.
Do not wrap the drain hose by pulling it.
When the drain hose must pass through indoor, it should be
wrapped by the special heat insulated materials.
The copper pipe and the drain hose must be wrapped by felt
strip. Heat insulated pad should be used between the connecting
pipe and the wall.
NOTE:
1
2
3
1
1
2
2
3
3
INSTALLATION
ROUTE OF PIPE
If pipe came out of the right side of the indoor unit, cut part
1 on the unit;
If pipe came out of the lower-right side of the indoor unit, cut p-
art "2" on the unit;
If pipe came out of the left side of the indoor unit, cut part 3
on the unit.
drain hose
gas pipe
liquid pipe
felt
adiabatic
underlay
drain hose
drain rubber
bib
REFIT OF DRAIN HOSE
If pipe comes out of the left side of the indoor unit,the drain hose
must be refit, otherwise water leakage may occur.
Refit methods: Interchange the position of drain hose and drain
rubber bib, the right diagram is before refit.
Clearance is not allowed after refit, it would lead to water leak.
Let pipe go through the wall hole and attach
the indoor unit to the mounting plate.(Locate
the rib of indoor unit in the hole of the mou-
nting plate.)
the rib of indoor unit
the mounting plate
Bottom
Indoor unit
14
4
Installation drain hose
15
5
Installation indoor unit
Indoor unit
terminal
Fastener
Connecting cable
Electrical box cover
Screw
Pull the connecting cable's
wire in completely
The wires have been connected
before. If there is any looseness,
please connect the cable accor-
ding the below processes.
NOTICE
1
1
Open the front panel;
Remove the screw from electrical box cover, pull the
electrical box cover away from the unit and set aside.
Remove the screw from fastener, pull the fastener
away from the unit and set aside.
Connect the cable.
Replace the fastener and electrical box cover.
2
2
3
3
4
4
5
5
Diagram
Screw
Indoor unit terminal
Connecting cable
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kalorik ka ac 26 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kalorik ka ac 26 in the language / languages: English as an attachment in your email.

The manual is 2,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kalorik ka ac 26

Kalorik ka ac 26 User Manual - German - 24 pages

Kalorik ka ac 26 User Manual - Dutch - 24 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info