5 Installation
WARNING Always use adequate personal protective
equipment (gloves, safety goggles and work clothing)
during installation and maintenance of the fireplace.
5.1 Placement
Installation is prohibited in the following situations:
In stairwells, with the exception of buildings with no more
than two residences;
In entrances that are accessible to everyone;
In spaces where highly flammable or explosive substances
or mixtures are processed, stored or manufactured;
In rooms or homes that are vented by air conditioning or air
heating by fans, with the exception of the following cases
where the risk-free functioning of the Kalfire is guaranteed:
- The installation only circulates air within the room;
- The installation has reliable safety provisions, so that
excess pressure is automatically created in the room with
the installed fireplace;
- The combustion air flow from the fireplace and the volume
flows of ventilation installations in the room and in the
rooms connected via venting airways create negative
pressure that remains below 0.04 mbar.
- Careful! This situation must also be safeguarded if easily
accessible control equipment used for the ventilating
installation is moved or removed.
- Fresh air is supplied via the air supply system to operate
the flue gas discharge system (e.g. through an open
window or a fresh air supply).
5.1.1 Working of combustion air
When the door is closed, the fire extracts the combustion air
directly from the connection at the rear (A) or bottom (A’).
This combustion air is guided into the combustion
chamber via de secondary air regulation (B) and the primary
thermostat (C), where it is used as primary or secondary
combustion air.
Primary combustion air (P)
The thermostat automatically regulates this airflow.
With a cold fireplace, the thermostat ensures that the air
enters the combustion chamber via the lower spoiler. As the
fireplace warms up, the air flow will gradually decrease. After
approximately 50 minutes, the fireplace will be so hot that this
airflow stops. The primary air regulation is 100% automatic and
cannot be influenced.
Secondary combustion air (S)
You control this airflow manually by moving the secondary air
regulation. This air, which is warmed up via risers to the left and
right of the combustion chamber, is guided to the combustion
chamber via the upper spoiler.
CAREFUL! Never entirely close the secondary air
regulation. Without airflow from the secondary air control,
the fire can suocate, causing the fireplace’s glass pane to
become soiled more quickly.
When the door is open, the air requirement of the fireplace
changes. A large volume of air will be sucked in through the large
opening at the front. This air will be taken from the room where
the fireplace is located.
When the door is open, the built-in fresh air valve ensures that the
passage of the air to the combustion chamber is closed from the
rear or bottom connection (see figures 14 - 16). Instead, the air is
diverted to the convection casing, after which it flows heated into
the room.
The air can then be used for the combustion process.
Figure 13: Cross-section of Kalfire W combustion air
S
P
A
A’C B
16
16


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kalfire W70-33F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kalfire W70-33F in the language / languages: English as an attachment in your email.

The manual is 8,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kalfire W70-33F

Kalfire W70-33F User Manual - German - 56 pages

Kalfire W70-33F User Manual - Dutch - 55 pages

Kalfire W70-33F User Manual - French - 55 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info