7 Maintenance
7.1 General instructions
Do not use steel brushes to clean a stainless steel flue duct.
Remove the bae plate before sweeping to remove the
soot and to ensure that the plate is not obstructing the
passage during sweeping.
Clean the space under the fireplace via the convection
grates at the base. A lot of dust can easily collect here,
conveyed by the convection current.
Make sure the cord in the lower frame is free of
ash and soiling.
If the cords no longer seal properly, they can be replaced.
Contact your Kalfire dealer for assistance.
Treat the chain in the lifting door system each year, by
spraying it with Kalfire lubrication.
The panel is made from special ceramic glass. This should
not be placed in the bottle bank. Ceramic glass does not
melt in the glass oven, so it will cause problems in the glass
oven. Your ceramic glass should be returned to your council
waste tip so it can be recycled appropriately.
Only use Kalfire spare parts as replacement parts (if
necessary). These parts can be obtained from your Kalfire
dealer.
7.2 Maintenance frequency
The wood burning fireplace should be inspected annually for
optimal, sustainable and safe use. Malfunctions to the wood
burning fireplace must be fixed instantly. Inform your client about
the possibilities of a maintenance contract.
7.3 Before and during the heating season
As time passes, tarnish can form on the inside of the glass. This
can be removed by using a moist cloth or non-scratching cleaning
detergent (ceramic glass cleaner). Do not use corrosive or
abrasive substances for cleaning the fireplace. Damage to enamel
is not included in the warranty. Small damaged can be removed
by using heat-resistant enamel. This enamel is available at Kalfire.
7.4 Keeping clean glass panes
In the case of an interior with steel slats or a design, the risk
of soiling the glass pane is greater than with the standard
(skamol) plates.
The Kalfire W80/52T, W105/47T and W53/50R models, as a
result of the relatively small surface skamol plates (which
provide the reflection), have a greater chance of dirtying
their glass pane.
Only burn dry wood.
Open the secondary air regulation completely.
Open the damper (if present) completely open.
Ensure the flue has a minimum draught of 12 Pa.
7.4.1 Cleaning ceramic panels
The first time it is used, afterwards as well, the glass of a wood-
burning fireplace can become dirty. Potential causes can be:
smoking materials in the fireplace (especially in the beginning),
air contamination, quality of the wood, etc.
•
Filth or stains on the glass must be removed immediately.
•
Never use the fireplace if the glass is filthy or stained. This
can lead to permanent and non-removable contamination.
•
Clean the glass after the burning a fire for the first time and
preferably after each use of the fireplace.
•
Use scratch-free cleaning substances only.
42
42


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kalfire W45-48F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kalfire W45-48F in the language / languages: English as an attachment in your email.

The manual is 8,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kalfire W45-48F

Kalfire W45-48F User Manual - German - 56 pages

Kalfire W45-48F User Manual - Dutch - 55 pages

Kalfire W45-48F User Manual - French - 55 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info