4.1.2 Checking the flue
To ensure proper functioning, we advise you to test/fire the
fireplace as early as possible (even before you have finished it
completely) (see Chapter 5):
You can then determine whether an external damper is
necessary.
The enamel on the fireplace can harden before it is finished.
This ensures less inconvenience for the user.
You will know at an early stage whether the fireplace and
flue are functioning properly.
Checks to be carried out while (test) burning
1. Check the flue for proper functioning; the minimum
required draught is 12 Pa.
2. Test the secondary air regulation for proper operation; this
works after 50 minutes of heating: (see Section 5.1.1)
- extreme right position = maximum supply of combustion
air
- extreme left position = air supply closed; fire slowly is
extinguished.
- if the flames do not react, or do not react enough, to
the change in the secondary air regulation, it may be
worthwhile considering installing an external damper on
the fireplace
3. Close all windows and doors (after about 50 minutes of
burning) and switch o any air consumers such as hoods,
fans, etc.
4. Then open the door of the fireplace to check that there is no
smoke returning (see also the conditions for installing the
fireplace (Section 5.1). If smoke is returning to the room, you
can consider adjusting the bae plates (see Section 5.5).
5. Use a little smoke to check the correct supply and
discharge of the convection air.
Figure 11: Opening the door to check the return of smoke to the room
Figure 12: Secondary air regulation
15
15


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kalfire W105-47T at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kalfire W105-47T in the language / languages: English as an attachment in your email.

The manual is 8,24 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kalfire W105-47T

Kalfire W105-47T User Manual - German - 56 pages

Kalfire W105-47T User Manual - Dutch - 55 pages

Kalfire W105-47T User Manual - French - 55 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info