694524
31
Zoom out
Zoom in
Previous page
1/40
Next page
31
Error code Cause Solution
08A
No
ionisation
measure-
ment during
ignition.
A flame is visible during ignition
1. Check if the ionisation pen is completely unobstructed
by looking into the fireplace.
2. Check if the plug in the technical box is correctly
connected.See Wiring diagram on page 36.
3. Check the connection with the ionisation pen and
whether there are damages to the ionisation cable.
4. Measure the ionisation signal.
No flame is visible during ignition, but there was a spark
at the ignition pen.
1. Remove the door from the fireplace (see 5.1.3 and 5.1.4)
2. Carefully check if there no decorative elements are
obstructing the pen and if the spark correctly ignites
the burner.
3. Ignite the gas fire without the door once and check if
gas is emanating from the burner. In case no gas ema-
nates from the burner: check for gas supply up to the
technical box (measure pre-pressure).
4. In the presence of pre-pressure, check whether the
cables running from the automatic burner relay to the
gas valve unit are damaged and/or disconnected.
5. In case of an excessive gas pressure level (>55mbar)
the gas valve cannot be opened for safety reasons.
The energy company or installer should fix this problem.
6. In case of no result: exchange gas regulator.
No flame is visible during ignition and no spark is visible
at the ignition pen.
1. Check whether the ignition pen is obstructed in
the fireplace.
2. Check if the plug connection is correct inside the
technical unit. See Wiring diagram on page 36.
3. Check if there is sufficient 24V D/C power supply.
4. Check the ignition cable for damages and check the
connection with the burner.
5. Check the HDIMS supply for the ignition transformer.
If the 135 V is supplied: replace the ignition
transformer,
if there is no 135 V: replace the HDIMS.
15A
Gas valve
problem
1. Check the cover wiring.
2. In case of correct wiring: exchange gas regulator.
31


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kalfire G105-37C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kalfire G105-37C in the language / languages: English as an attachment in your email.

The manual is 1,55 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kalfire G105-37C

Kalfire G105-37C User Manual - German - 44 pages

Kalfire G105-37C User Manual - Dutch - 41 pages

Kalfire G105-37C User Manual - French - 45 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info