685872
22
Zoom out
Zoom in
Previous page
1/26
Next page
20
POSSIBLE CAUSE
Faulty transformer.
Fuse blown.
Faulty solenoid coil.
Incorrect wiring or bad
wiring connection.
Incorrect programming
or blown fuse.
Short on keypad or
programming not
correct.
Too many start times
entered on automatic
programs.
Damaged main output
driver chip.
Faulty relay or pump
contactor.
Display damaged
during transportation.
TROUBLESHOOTING
SYMPTOM
No display.
Single Station
not working.
Fuse blows.
No automatic
start.
Buttons on
keypad not
responding.
System coming
on at random.
More than 1
station coming
on at once.
Pump start
chattering.
Display cracked
or missing
segments.
SUGGESTION
Check fuse. Check field wiring.
Check transformer.
Swap faulty station wire on controller
terminal block with known working
station wire. If the faulty valve still
does not work on the known working
connection then the solenoid coil
is faulty. The panel may need to be
repaired.
Check wiring and connections.
If unit works manually check
programming. Check fuse and field
wiring.
Check instruction book to ensure
programming correct. If keypad still not
responding return panel to supplier or
manufacturer.
Check number of start times entered on
each program. If programming is correct
return panel to supplier or manufacturer.
Check wiring and swap faulty station
wire(s) on controller terminal block with
known working station wire. If the same
outputs are still locked on, return panel
to supplier or manufacturer.
Electrician to check voltage on pump
relay or contactor.
Return panel to supplier or
manufacturer.
22


Need help? Post your question in this forum.

Forumrules
1

Forum

k-rain-rps46

Reset search

  • I am not too sure on the wiring outside the house onto valves and solenoids. My fuses keep blowing so I was wondering if I could get a diagram for this please thanks. Submitted on 6-5-2021 at 17:04

    Reply Report abuse
  • I would like a photograph of the wire hookups to the solenoids and valves outside as my fuse keeps blowing please thanks. Submitted on 6-5-2021 at 16:55

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for K-rain RPS46 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of K-rain RPS46 in the language / languages: English as an attachment in your email.

The manual is 0,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info