685878
29
Zoom out
Zoom in
Previous page
1/36
Next page
27
COM
COM COM
SENS PUMP 1 ST1 ST2 ST3 ST4 ST5 ST6
PUMP 2
Valve Common Wire
Master Valve
Valve 1 Valve 2 Valve 3 Valve 4
Pump Protection (System Test)
In some circumstances not all operational stations might be hooked up. For example,
if the controller was capable of running 6 stations but there were only 4 eld wires
and solenoid valves available for connection. This situation can pose a risk to a pump
when the system test routine for the controller is initiated.
The system test routine sequences through all available stations on the controller. In
the above example this would mean stations 5 through to 6 would become active and
would cause the pump to operate against a closed head. This could possibly cause
permanent pump, pipe and pressure vessel damage.
It is mandatory if the system test routine is going to be used, that all unused, spare
stations, should be linked together and then looped to the last working station with a
valve on it.
Using the above example, the connector block should be wired as per the diagram
below.
COM
COM COM
SENS PUMP 1 ST1 ST2 ST3 ST4 ST5 ST6
PUMP 2
Link any unused
stations to the
last active station.
INSTALLATION INSTRUCTIONS
0207P8011_RPS624_Instruction_Manual-FINAL-USA.indd 27 21/08/2015 9:13 am
29


Need help? Post your question in this forum.

Forumrules
1

Forum

k-rain-rps-624

Reset search

  • sprinklers dont come on sequentially only one station out of four Submitted on 10-3-2022 at 22:28

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for K-rain RPS 624 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of K-rain RPS 624 in the language / languages: English as an attachment in your email.

The manual is 5,67 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info